2007Anhui Medical and Pharmaceutical JournalRequires access

Determination of chlorogenic acid in xiaoerkechuanling gel by HPLC

Dong-Mei Xie

Open publisher page 0 citations

Abstract

Aim To determine chlorogenic acid in xiaoerkechuanling gel by HPLC.Methods HPLC was used in the quantitative analysis of chlorogenic acid in the sample.The separation was performed on hanbon C18(4.6 mm×250 mm,5 μm)column with a mixture of acetonitrile-0.4% phosphoric acid(13∶87) as mobile phase.The detection wavelengh was set at 327 nm and the flow rate was 1.0 ml·min-1.Results The standard curve was linear in the range of 0.168~0.84 μg for chlorogenic acid(r=0.9996,n=5).The average recovery was 98.55%.Conclusion The method is simple,reliable,and is a good method to determinate chlorogenic acid.

About this research paper

What this paper is about

Aim To determine chlorogenic acid in xiaoerkechuanling gel by HPLC.Methods HPLC was used in the quantitative analysis of chlorogenic acid in the sample.The separation was performed on hanbon C18(4.6 mm×250 mm,5 μm)column with a mixture of acetonitrile-0.4% phosphoric acid(13∶87) as mobile phase.The detection wavelengh was set at 327 nm and the flow rate was 1.0 ml·min-1.Results The standard curve was linear in the range of 0.168~0.84 μg for chlorogenic acid(r=0.9996,n=5).The average recovery was 98.55%.Conclusion The method is simple,reliable,and is a good method to determinate chlorogenic acid.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim To determine chlorogenic acid in xiaoerkechuanling gel by HPLC.Methods HPLC was used in the quantitative analysis of chlorogenic acid in the sample.The separation was performed on hanbon C18(4.6 mm×250 mm,5 μm)column with a mixture of acetonitrile-0.4% phosphoric acid(13∶87) as mobile phase.The detection wavelengh was set at 327 nm and the flow rate was 1.0 ml·min-1.Results The standard curve was linear in the range of 0.168~0.84 μg for chlorogenic acid(r=0.9996,n=5).The average recovery was 98.55%.Conclusion The method is simple,reliable,and is a good method to determinate chlorogenic acid.

Key concepts: Chlorogenic acid, Chromatography, Phosphoric acid, High-performance liquid chromatography, Chemistry, Acetonitrile, Linear range, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of chlorogenic acid in xiaoerkechuanling gel by HPLC — Research Paper | ScholarLens