2010•Zhongguo yaofangRequires access

Content Determination of Chlorogenic Acid in Rheumatoid II Mixture by HPLC

Jiancheng Zhu

Open publisher page 0 citations

Abstract

OBJECTIVE: To establish HPLC method for the content determination of chlorogenic acid in Rheumatoid Ⅱ mixture. METHODS: The determination was performed on Diamonsil C18(200 mm×4.6 mm,5 μm) column with mobile phase consisted of acetonitrile-0.4% phosphoric acid (10 ∶ 90) and detection wavelength of 327 nm. RESULTS: The linear range of chlorogenic acid was 24.2~193.6 μg·mL-1(r=0.999 9) with an average recovery of 99.23% (RSD=1.05%,n=9). CONCLUSION: The method is accurate, sensitive and reproducible for the quality control of Rheumatoid Ⅱ mixture.

About this research paper

What this paper is about

OBJECTIVE: To establish HPLC method for the content determination of chlorogenic acid in Rheumatoid Ⅱ mixture. METHODS: The determination was performed on Diamonsil C18(200 mm×4.6 mm,5 μm) column with mobile phase consisted of acetonitrile-0.4% phosphoric acid (10 ∶ 90) and detection wavelength of 327 nm. RESULTS: The linear range of chlorogenic acid was 24.2~193.6 μg·mL-1(r=0.999 9) with an average recovery of 99.23% (RSD=1.05%,n=9). CONCLUSION: The method is accurate, sensitive and reproducible for the quality control of Rheumatoid Ⅱ mixture.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To establish HPLC method for the content determination of chlorogenic acid in Rheumatoid Ⅱ mixture. METHODS: The determination was performed on Diamonsil C18(200 mm×4.6 mm,5 μm) column with mobile phase consisted of acetonitrile-0.4% phosphoric acid (10 ∶ 90) and detection wavelength of 327 nm. RESULTS: The linear range of chlorogenic acid was 24.2~193.6 μg·mL-1(r=0.999 9) with an average recovery of 99.23% (RSD=1.05%,n=9). CONCLUSION: The method is accurate, sensitive and reproducible for the quality control of Rheumatoid Ⅱ mixture.

Key concepts: Chlorogenic acid, Phosphoric acid, Chromatography, High-performance liquid chromatography, Chemistry, Linear range, Content determination, Linear relationship

Related papers

Back to paper searchBrowse research topicsOriginal source
Content Determination of Chlorogenic Acid in Rheumatoid II Mixture by HPLC — Research Paper | ScholarLens