2009•Journal of Putian UniversityRequires access

Determination of Oleanolic Acid in the Sedum Aizoon by HPLC

Xueqin Xu

Open publisher page 1 citations

Abstract

Objective: To find out a method using high-performance liquid chromatography to measure Sedum aizoon oleanolic acid.Method: high-performance liquid chromatography with Hypersil ODS(5μm,250mm×4.0 mm) column,a mobile phase of methanol : 0.1 % phosphoric acid(80:20),detected the bones at 215 nm and tendons of grass in oleanolic acid content.The results showed that the linearity range of determination is 10.0—100.0μg·mL-1.The average recovery rate is100.4%.Conclusion: This method is simple,rapid,sensitive,accurate and reproducible.It can be used as a method determining the oleanolic acid in Sedum aizoon.

About this research paper

What this paper is about

Objective: To find out a method using high-performance liquid chromatography to measure Sedum aizoon oleanolic acid.Method: high-performance liquid chromatography with Hypersil ODS(5μm,250mm×4.0 mm) column,a mobile phase of methanol : 0.1 % phosphoric acid(80:20),detected the bones at 215 nm and tendons of grass in oleanolic acid content.The results showed that the linearity range of determination is 10.0—100.0μg·mL-1.The average recovery rate is100.4%.Conclusion: This method is simple,rapid,sensitive,accurate and reproducible.It can be used as a method determining the oleanolic acid in Sedum aizoon.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To find out a method using high-performance liquid chromatography to measure Sedum aizoon oleanolic acid.Method: high-performance liquid chromatography with Hypersil ODS(5μm,250mm×4.0 mm) column,a mobile phase of methanol : 0.1 % phosphoric acid(80:20),detected the bones at 215 nm and tendons of grass in oleanolic acid content.The results showed that the linearity range of determination is 10.0—100.0μg·mL-1.The average recovery rate is100.4%.Conclusion: This method is simple,rapid,sensitive,accurate and reproducible.It can be used as a method determining the oleanolic acid in Sedum aizoon.

Key concepts: Oleanolic acid, High-performance liquid chromatography, Phosphoric acid, Chromatography, Chemistry, Sedum, Biology, Botany

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Oleanolic Acid in the Sedum Aizoon by HPLC — Research Paper | ScholarLens