Effect of continuous positive airway pressure on characteristics of polysomnography of obstructive sleep apnea-hypopnea syndrome
Zhijian Lei
Abstract
Zhijian Lei
Abstract
Objective:To explore how continuous positive airway pressure(CPAP)affects characteristics of polysomnography(PSG)of patients with obstructive sleep apnea-hypopnea syndrome(OSAHS)and after the pressure titration was made by Auto-continuous positive airway pressure(Auto-CPAP).Methods:A computer-assistant diagnostic system was used for polysomnography(PSG)recording.The characteristics of PSG between 70 non-OSAHS patients(control group)and 78 OSAHS patients were analyzed.40 OSAHS patients accepted CPAP therapy after auto-CPAP pressure titration was finished,and were abserved the change of the parameter of the PSG both before and during CPAP treatment.Results:Compared with controls,OSAHS group had a significant difference in sleep structure,respiratory events,arterial oxygen saturation(SaO2)and the other parameters changes of characteristics of the PSG(P0.05),which were manifested as less NREM Ⅲ+Ⅳ,more NREM Ⅰ+Ⅱ,less REM sleep,increased number of WASO(wake after sleep onset),shortened sleep latency(SL),more apnea-hypopnea index(AHI),decrease of nighttime mean SaO2(M SaO2)and the lowest SaO2(LSaO2)and increased the cumulated time of less than 90% SaO2 over total sleep time(90%T).After the pressure titration was made by Auto-CPAP,all the parameters mentioned above were different degree improved by CPAP treatment(P0.05).Conclusions:OSAHS patients have the characteristics of the PSG in sleep structure disorders,respiratory disorder and hypoxemia.CPAP therapy can improve the characteristics of the PSG of patients with OSAHS in short-term after the pressure titration was made by Auto-CPAP,it is a safe,non-invasive,brief and effective method to treat OSAHS.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To explore how continuous positive airway pressure(CPAP)affects characteristics of polysomnography(PSG)of patients with obstructive sleep apnea-hypopnea syndrome(OSAHS)and after the pressure titration was made by Auto-continuous positive airway pressure(Auto-CPAP).Methods:A computer-assistant diagnostic system was used for polysomnography(PSG)recording.The characteristics of PSG between 70 non-OSAHS patients(control group)and 78 OSAHS patients were analyzed.40 OSAHS patients accepted CPAP therapy after auto-CPAP pressure titration was finished,and were abserved the change of the parameter of the PSG both before and during CPAP treatment.Results:Compared with controls,OSAHS group had a significant difference in sleep structure,respiratory events,arterial oxygen saturation(SaO2)and the other parameters changes of characteristics of the PSG(P0.05),which were manifested as less NREM Ⅲ+Ⅳ,more NREM Ⅰ+Ⅱ,less REM sleep,increased number of WASO(wake after sleep onset),shortened sleep latency(SL),more apnea-hypopnea index(AHI),decrease of nighttime mean SaO2(M SaO2)and the lowest SaO2(LSaO2)and increased the cumulated time of less than 90% SaO2 over total sleep time(90%T).After the pressure titration was made by Auto-CPAP,all the parameters mentioned above were different degree improved by CPAP treatment(P0.05).Conclusions:OSAHS patients have the characteristics of the PSG in sleep structure disorders,respiratory disorder and hypoxemia.CPAP therapy can improve the characteristics of the PSG of patients with OSAHS in short-term after the pressure titration was made by Auto-CPAP,it is a safe,non-invasive,brief and effective method to treat OSAHS.
Key concepts: Polysomnography, Continuous positive airway pressure, Medicine, Non-rapid eye movement sleep, Anesthesia, Hypopnea, Obstructive sleep apnea, Hypoxemia