Comparability analysis and bias evaluation on results of TSH measured at different detection systems

Li Na

Open publisher page 0 citations

Abstract

Objective:To explore and evaluate the comparability and bias of the results of TSH measured in two different immune luminescence analysis systems.Methods:According to the U.S.Committee for Clinical Laboratory Standards(NCCLS) EP9-A2,9 clinic samples were detected in two kinds of different analysis systems(Siemens Immulite2000 and Roche E170) respectively everyday.The testing results of total 45 samples were recorded within 5 days.The testing results derived from two analysis systems were analyzed comparatively and their biases were evaluated.Results:The TSH results between the two detection systems were significantly different(P0.01),but the correlation between them was good.The regression equation was y=0.9639x+0.0453,R2=0.998.Use Siemens Immulite2000 analysis system as a control method,the TSH anticipated bias of Roche E170 was within allowed biases,which was acceptable by clinic.Conclusion:The TSH results between the two detection systems were significantly different,but it can be accepted by clinic.

About this research paper

What this paper is about

Objective:To explore and evaluate the comparability and bias of the results of TSH measured in two different immune luminescence analysis systems.Methods:According to the U.S.Committee for Clinical Laboratory Standards(NCCLS) EP9-A2,9 clinic samples were detected in two kinds of different analysis systems(Siemens Immulite2000 and Roche E170) respectively everyday.The testing results of total 45 samples were recorded within 5 days.The testing results derived from two analysis systems were analyzed comparatively and their biases were evaluated.Results:The TSH results between the two detection systems were significantly different(P0.01),but the correlation between them was good.The regression equation was y=0.9639x+0.0453,R2=0.998.Use Siemens Immulite2000 analysis system as a control method,the TSH anticipated bias of Roche E170 was within allowed biases,which was acceptable by clinic.Conclusion:The TSH results between the two detection systems were significantly different,but it can be accepted by clinic.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To explore and evaluate the comparability and bias of the results of TSH measured in two different immune luminescence analysis systems.Methods:According to the U.S.Committee for Clinical Laboratory Standards(NCCLS) EP9-A2,9 clinic samples were detected in two kinds of different analysis systems(Siemens Immulite2000 and Roche E170) respectively everyday.The testing results of total 45 samples were recorded within 5 days.The testing results derived from two analysis systems were analyzed comparatively and their biases were evaluated.Results:The TSH results between the two detection systems were significantly different(P0.01),but the correlation between them was good.The regression equation was y=0.9639x+0.0453,R2=0.998.Use Siemens Immulite2000 analysis system as a control method,the TSH anticipated bias of Roche E170 was within allowed biases,which was acceptable by clinic.Conclusion:The TSH results between the two detection systems were significantly different,but it can be accepted by clinic.

Key concepts: Comparability, Siemens, Statistics, Mathematics, Medicine, Engineering, Combinatorics, Electrical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparability analysis and bias evaluation on results of TSH measured at different detection systems — Research Paper | ScholarLens