2007Yunnan Journal of Traditional Chinese Medicine and Materia MedicaRequires access

Determination of Catechin Content in New Antasthmatic Mixture by High-performance Liquid Chromatography

LI Ren-qiu

Open publisher page 0 citations

Abstract

Objective: To establish a high-performance liquid chromatography to determine the catechin content in new antasthmatic mixture.Method: Dikma C18 column(4.6 mm×250 mm,5μm) was used.The mobile phase was acetonitrile-0.2%phosphoric acid solution(8:92).The determination wavelength was 280 mm.The mobile speed was 1.0ml/min.the coloumn temperature was 35oC.Result: The catechin content was within 0.0425-4.25μg(r=0.99999) and had a good linear relation with peak area.The average recoveray rate was 99.05%,RSD=0.72%(n=9).Conclusion: The method is simple,convenient and quick,with a strong exclusive and a good reappearance and can be used in the quality control of the new antasthmatic mixture.

About this research paper

What this paper is about

Objective: To establish a high-performance liquid chromatography to determine the catechin content in new antasthmatic mixture.Method: Dikma C18 column(4.6 mm×250 mm,5μm) was used.The mobile phase was acetonitrile-0.2%phosphoric acid solution(8:92).The determination wavelength was 280 mm.The mobile speed was 1.0ml/min.the coloumn temperature was 35oC.Result: The catechin content was within 0.0425-4.25μg(r=0.99999) and had a good linear relation with peak area.The average recoveray rate was 99.05%,RSD=0.72%(n=9).Conclusion: The method is simple,convenient and quick,with a strong exclusive and a good reappearance and can be used in the quality control of the new antasthmatic mixture.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To establish a high-performance liquid chromatography to determine the catechin content in new antasthmatic mixture.Method: Dikma C18 column(4.6 mm×250 mm,5μm) was used.The mobile phase was acetonitrile-0.2%phosphoric acid solution(8:92).The determination wavelength was 280 mm.The mobile speed was 1.0ml/min.the coloumn temperature was 35oC.Result: The catechin content was within 0.0425-4.25μg(r=0.99999) and had a good linear relation with peak area.The average recoveray rate was 99.05%,RSD=0.72%(n=9).Conclusion: The method is simple,convenient and quick,with a strong exclusive and a good reappearance and can be used in the quality control of the new antasthmatic mixture.

Key concepts: Catechin, Phosphoric acid, Chromatography, Chemistry, High-performance liquid chromatography, Acetonitrile, Content determination, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Catechin Content in New Antasthmatic Mixture by High-performance Liquid Chromatography — Research Paper | ScholarLens