2008Yunnan Journal of Traditional Chinese Medicine and Materia MedicaRequires access

Determination of Liquritin in New Antasthmatic Liquid Mixture by HPLC

LI Ren-qiu

Open publisher page 0 citations

Abstract

Objective:To establish a method of HPLC for the determination of liquritin in new antasthmatic liquid mixture. Methods: The Dikma C18 column (4.6mm×250mm, 5μm) was used. The mobile phase was acetonitrile-0.5% glacial acetic acid (20:80). The flow rate was 1.0ml/min with a detective wavelength of 276nm and a column temperature of 30oC. Results: The sample volume of liquiritin at the range of 0.02-1.0μg, ( r=0.99990) has a good linear relation with the peak area. The average recovery rate was 99.27%, RSD=0.67% (n=9). Conclusion: The method is convenient, accurate and exclusive with good reappearance and can be used to control the quality of reproducible the new antasthmatic liquid mixture.

About this research paper

What this paper is about

Objective:To establish a method of HPLC for the determination of liquritin in new antasthmatic liquid mixture. Methods: The Dikma C18 column (4.6mm×250mm, 5μm) was used. The mobile phase was acetonitrile-0.5% glacial acetic acid (20:80). The flow rate was 1.0ml/min with a detective wavelength of 276nm and a column temperature of 30oC. Results: The sample volume of liquiritin at the range of 0.02-1.0μg, ( r=0.99990) has a good linear relation with the peak area. The average recovery rate was 99.27%, RSD=0.67% (n=9). Conclusion: The method is convenient, accurate and exclusive with good reappearance and can be used to control the quality of reproducible the new antasthmatic liquid mixture.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a method of HPLC for the determination of liquritin in new antasthmatic liquid mixture. Methods: The Dikma C18 column (4.6mm×250mm, 5μm) was used. The mobile phase was acetonitrile-0.5% glacial acetic acid (20:80). The flow rate was 1.0ml/min with a detective wavelength of 276nm and a column temperature of 30oC. Results: The sample volume of liquiritin at the range of 0.02-1.0μg, ( r=0.99990) has a good linear relation with the peak area. The average recovery rate was 99.27%, RSD=0.67% (n=9). Conclusion: The method is convenient, accurate and exclusive with good reappearance and can be used to control the quality of reproducible the new antasthmatic liquid mixture.

Key concepts: Chromatography, Liquiritin, High-performance liquid chromatography, Acetonitrile, Acetic acid, Chemistry, Analytical Chemistry (journal), Volumetric flow rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Liquritin in New Antasthmatic Liquid Mixture by HPLC — Research Paper | ScholarLens