2004Packaging EngineeringRequires access

Study on the Determination of Trace Lead and Cadmium in Fresh-Keeping Film by ICP-MS

Xiao‐Mei He

Open publisher page 0 citations

Abstract

Separation by 4% acetic acid extraction, trace Pb and Cd in fresh-keeping membrane was determined by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS). The optimum conditions for the determination was tested and discussed. The inspecting limit of the method were 0.03μg/L(Pb), 0.02μg/L (Cd). The recycling rate ranks from 94.4% to 104.2%. RSD is less than 2.02%. The method is accurate, quick and convenient. It can be used in the determination of trace Lead and Cadmium in fresh-keeping membrane with satisfactory result.

About this research paper

What this paper is about

Separation by 4% acetic acid extraction, trace Pb and Cd in fresh-keeping membrane was determined by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS). The optimum conditions for the determination was tested and discussed. The inspecting limit of the method were 0.03μg/L(Pb), 0.02μg/L (Cd). The recycling rate ranks from 94.4% to 104.2%. RSD is less than 2.02%. The method is accurate, quick and convenient. It can be used in the determination of trace Lead and Cadmium in fresh-keeping membrane with satisfactory result.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Separation by 4% acetic acid extraction, trace Pb and Cd in fresh-keeping membrane was determined by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS). The optimum conditions for the determination was tested and discussed. The inspecting limit of the method were 0.03μg/L(Pb), 0.02μg/L (Cd). The recycling rate ranks from 94.4% to 104.2%. RSD is less than 2.02%. The method is accurate, quick and convenient. It can be used in the determination of trace Lead and Cadmium in fresh-keeping membrane with satisfactory result.

Key concepts: Cadmium, Inductively coupled plasma mass spectrometry, Chemistry, Extraction (chemistry), TRACE (psycholinguistics), Recovery rate, Detection limit, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Determination of Trace Lead and Cadmium in Fresh-Keeping Film by ICP-MS — Research Paper | ScholarLens