2002•Unpublished venueRequires access

Study on commutation failure in an HVDC inverter

Zou Gang, Zheng Jian-chao, Chen Xiangxun

Open publisher page 13 citations

Abstract

Commutation failures (CF) are very frequent dynamic events in HVDC power systems. In this paper, a simplified thyristor lumped-charge model is used to analyze the change of the stored charges in the device during turn-off and the commutation process in an HVDC inverter is studied theoretically. The influences of external circuit parameters, as well as thyristor device parameters on CF, are examined. Based on the removal process of the stored charges in thyristor devices, the duration of the phases in turn-off process of the device is given and a novel criterion of commutation failure is proposed.

About this research paper

What this paper is about

Commutation failures (CF) are very frequent dynamic events in HVDC power systems. In this paper, a simplified thyristor lumped-charge model is used to analyze the change of the stored charges in the device during turn-off and the commutation process in an HVDC inverter is studied theoretically. The influences of external circuit parameters, as well as thyristor device parameters on CF, are examined. Based on the removal process of the stored charges in thyristor devices, the duration of the phases in turn-off process of the device is given and a novel criterion of commutation failure is proposed.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Commutation failures (CF) are very frequent dynamic events in HVDC power systems. In this paper, a simplified thyristor lumped-charge model is used to analyze the change of the stored charges in the device during turn-off and the commutation process in an HVDC inverter is studied theoretically. The influences of external circuit parameters, as well as thyristor device parameters on CF, are examined. Based on the removal process of the stored charges in thyristor devices, the duration of the phases in turn-off process of the device is given and a novel criterion of commutation failure is proposed.

Key concepts: Commutation, Thyristor, Integrated gate-commutated thyristor, Inverter, Control theory (sociology), Power (physics), Process (computing), MOS-controlled thyristor

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on commutation failure in an HVDC inverter — Research Paper | ScholarLens