Description of recent changes in the Langley 6- by 28-inch transonic tunnel
W. G. Sewall
Abstract
W. G. Sewall
Abstract
Calibrations were obtained in the Langley 6 by 28-inch transonic tunnel with newly installed controllable reentry flaps and test section floor and ceiling. Using available theory, the top and bottom slotted walls were redesigned for minimum wind tunnel interference errors of blockage and stream-line curvature. To minimize Mach number gradients along the tunnel axis downstream of the model, controllable flaps were installed to regulate the flow reentering the test section through the slotted walls. The flap setting is independent of stagnation pressure and varies only with Mach number. The freestream Mach number is determined from the pressrue measured at a station 66.04 cm upstream of the model station. The model has no significant influence on the vertical Mach number distribution at this station. This method of Mach number determination appears to be more accurate than one using the plenum pressure.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Calibrations were obtained in the Langley 6 by 28-inch transonic tunnel with newly installed controllable reentry flaps and test section floor and ceiling. Using available theory, the top and bottom slotted walls were redesigned for minimum wind tunnel interference errors of blockage and stream-line curvature. To minimize Mach number gradients along the tunnel axis downstream of the model, controllable flaps were installed to regulate the flow reentering the test section through the slotted walls. The flap setting is independent of stagnation pressure and varies only with Mach number. The freestream Mach number is determined from the pressrue measured at a station 66.04 cm upstream of the model station. The model has no significant influence on the vertical Mach number distribution at this station. This method of Mach number determination appears to be more accurate than one using the plenum pressure.
Key concepts: Transonic, Freestream, Mach number, Subsonic and transonic wind tunnel, Wind tunnel, Hypersonic wind tunnel, Plenum space, Supersonic wind tunnel