2023International Journal of Social healthOpen access

Imdose Phantom Development For Quality Assurance And Control In Computed Tomography Imaging Study Of Image Quality And Dosage Assessment

Djuli Pontjowijono, Donny Kristanto Mulyantoro, Rini Indrati

Open full text 0 citations

Abstract

C.T. has made a great contribution to detecting and diagnosing patients' diseases. C.T., before being applied to patients, must pass quality assurance and control with phantom. However, the availability of phantoms is still minimal because of their high price. His study aims to create and evaluate cylindrical phantoms for quality assurance and control procedures based on image quality and dose parameters. The research method involves creating an image-quality phantom design that references the CatPhan phantom using Sketchup. The results show that the phantom image provides results from the standard phantom; the SNR, CNR, MTF, noise, and MTF values of the ImDose phantom are still within the standard phantom criteria. Based on statistical tests, the image quality of SNR, CNR, MTF, NPS, and noise is not statistically significantly different from the standard phantom (p > 0.05). The uniformity value still needs to be improved because it has a significant difference from the standard phantom with an ap value <0.05. Increasing the voltage and current gave results proportional to improving image quality and dose. ImDose phantoms for quality assurance and C.T. control have been successfully developed.

Open-access reader

About this research paper

What this paper is about

C.T. has made a great contribution to detecting and diagnosing patients' diseases. C.T., before being applied to patients, must pass quality assurance and control with phantom. However, the availability of phantoms is still minimal because of their high price. His study aims to create and evaluate cylindrical phantoms for quality assurance and control procedures based on image quality and dose parameters. The research method involves creating an image-quality phantom design that references the CatPhan phantom using Sketchup. The results show that the phantom image provides results from the standard phantom; the SNR, CNR, MTF, noise, and MTF values of the ImDose phantom are still within the standard phantom criteria. Based on statistical tests, the image quality of SNR, CNR, MTF, NPS, and noise is not statistically significantly different from the standard phantom (p > 0.05). The uniformity value still needs to be improved because it has a significant difference from the standard phantom with an ap value <0.05. Increasing the voltage and current gave results proportional to improving image quality and dose. ImDose phantoms for quality assurance and C.T. control have been successfully developed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

C.T. has made a great contribution to detecting and diagnosing patients' diseases. C.T., before being applied to patients, must pass quality assurance and control with phantom. However, the availability of phantoms is still minimal because of their high price. His study aims to create and evaluate cylindrical phantoms for quality assurance and control procedures based on image quality and dose parameters. The research method involves creating an image-quality phantom design that references the CatPhan phantom using Sketchup. The results show that the phantom image provides results from the standard phantom; the SNR, CNR, MTF, noise, and MTF values of the ImDose phantom are still within the standard phantom criteria. Based on statistical tests, the image quality of SNR, CNR, MTF, NPS, and noise is not statistically significantly different from the standard phantom (p > 0.05). The uniformity value still needs to be improved because it has a significant difference from the standard phantom with an ap value <0.05. Increasing the voltage and current gave results proportional to improving image quality and dose. ImDose phantoms for quality assurance and C.T. control have been successfully developed.

Key concepts: Imaging phantom, Quality assurance, Image quality, Quality (philosophy), Noise (video), Medical physics, Nuclear medicine, Contrast-to-noise ratio

Related papers

Back to paper searchBrowse research topicsOriginal source
Imdose Phantom Development For Quality Assurance And Control In Computed Tomography Imaging Study Of Image Quality And Dosage Assessment — Research Paper | ScholarLens