2021Benha Medical JournalOpen access

Comparison Of Intraocular Pressure (IOP) Measured By Non-Contact (Air–Puff) Tonometer Compared With Goldmann Applanation Tonometer

Rowaida Basuony, Waheed Orouk, Tarek Soliman, Tarek N. Attia

Open full text 5 citations

Abstract

Background: Measurement of intraocular pressure is one of the most important examination procedures in ophthalmic clinics, IOP is an important parameter in the diagnosis of glaucoma. There are numerous types of tonometers available, it is important to evaluate the differences in readings between different tonometers. Goldmann Applanation Tonometers and non-contact Air-Puff Tonometers are largely available in ophthalmic clinics.Aim: The purpose of this study is to evaluate the difference between IOP measurements taken by a GAT and those taken by an Air Puff Tonometer and to observe the reliability of Air Puff to be a screening tool.Material and Methods: This study was performed on 200 eyes from 100 study participants (including: Relatives of patients, medical students, nurses and patients complaining from errors of refraction). attending an ophthalmic outpatient clinic. visual acuity, Refraction, fundus examination, corneal thickness were assessed for each participant; Also, each patient’s IOP was measured using both GAT and Air-Puff tonometry, the difference in readings between the two methods were calculated.Result: The mean IOP measured by GAT was 14.48±2.29 mmHg, while that measured by Air Puff tonometer was 16.34±2.3 mmHg. The mean difference between the two methods of measurement was 1.855 mmHg. The readings obtained by Air Puff tonometer were higher than those obtained by GAT and highly statistically significant.Conclusion: The non-contact, air puff, tonometer produces IOP measurements which are similar & consistent to that of gold standard GAT. Our study indicated that there is a good consistency between the non-contact Air-Puff tonometer and GAT.

Open-access reader

About this research paper

What this paper is about

Background: Measurement of intraocular pressure is one of the most important examination procedures in ophthalmic clinics, IOP is an important parameter in the diagnosis of glaucoma. There are numerous types of tonometers available, it is important to evaluate the differences in readings between different tonometers. Goldmann Applanation Tonometers and non-contact Air-Puff Tonometers are largely available in ophthalmic clinics.Aim: The purpose of this study is to evaluate the difference between IOP measurements taken by a GAT and those taken by an Air Puff Tonometer and to observe the reliability of Air Puff to be a screening tool.Material and Methods: This study was performed on 200 eyes from 100 study participants (including: Relatives of patients, medical students, nurses and patients complaining from errors of refraction). attending an ophthalmic outpatient clinic. visual acuity, Refraction, fundus examination, corneal thickness were assessed for each participant; Also, each patient’s IOP was measured using both GAT and Air-Puff tonometry, the difference in readings between the two methods were calculated.Result: The mean IOP measured by GAT was 14.48±2.29 mmHg, while that measured by Air Puff tonometer was 16.34±2.3 mmHg. The mean difference between the two methods of measurement was 1.855 mmHg. The readings obtained by Air Puff tonometer were higher than those obtained by GAT and highly statistically significant.Conclusion: The non-contact, air puff, tonometer produces IOP measurements which are similar & consistent to that of gold standard GAT. Our study indicated that there is a good consistency between the non-contact Air-Puff tonometer and GAT.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Measurement of intraocular pressure is one of the most important examination procedures in ophthalmic clinics, IOP is an important parameter in the diagnosis of glaucoma. There are numerous types of tonometers available, it is important to evaluate the differences in readings between different tonometers. Goldmann Applanation Tonometers and non-contact Air-Puff Tonometers are largely available in ophthalmic clinics.Aim: The purpose of this study is to evaluate the difference between IOP measurements taken by a GAT and those taken by an Air Puff Tonometer and to observe the reliability of Air Puff to be a screening tool.Material and Methods: This study was performed on 200 eyes from 100 study participants (including: Relatives of patients, medical students, nurses and patients complaining from errors of refraction). attending an ophthalmic outpatient clinic. visual acuity, Refraction, fundus examination, corneal thickness were assessed for each participant; Also, each patient’s IOP was measured using both GAT and Air-Puff tonometry, the difference in readings between the two methods were calculated.Result: The mean IOP measured by GAT was 14.48±2.29 mmHg, while that measured by Air Puff tonometer was 16.34±2.3 mmHg. The mean difference between the two methods of measurement was 1.855 mmHg. The readings obtained by Air Puff tonometer were higher than those obtained by GAT and highly statistically significant.Conclusion: The non-contact, air puff, tonometer produces IOP measurements which are similar & consistent to that of gold standard GAT. Our study indicated that there is a good consistency between the non-contact Air-Puff tonometer and GAT.

Key concepts: Goldmann Applanation Tonometer, Intraocular pressure, Medicine, Ophthalmology, Glaucoma, Optometry, Significant difference, Applanation tonometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison Of Intraocular Pressure (IOP) Measured By Non-Contact (Air–Puff) Tonometer Compared With Goldmann Applanation Tonometer — Research Paper | ScholarLens