Sodium Alginate Ultrasound Phantom for Medical Education
Minoru Aoyagi
Abstract
Minoru Aoyagi
Abstract
The ultrasound phantoms used to educate medical students should not only closely mimic the ultrasound characteristics of human soft tissues but also be inexpensive and easy to manufacture. I have been studying handmade ultrasound phantoms and proposed an ultrasound phantom comprising calcium alginate hydrogel that met these requirements but caused a speckle pattern similar to that observed in ultrasound images of liver. In this study, I show that adding ethanol to the precursors used to fabricate the phantom reduces the speckle pattern. The ultrasound propagation velocity and attenuation coefficient of the phantom were 1561 ± 8 m/s and 0.54 ± 0.18 dB/cm/MHz, respectively (mean ± standard deviation), which are within the ranges of those in human soft tissues (1530-1600 m/s and 0.3-1.0 dB/cm/MHz, respectively). This phantom is easy to fabricate without special equipment, is inexpensive, and is suitable for elementary training on ultrasound diagnosis, operation of ultrasound-guided needles, and blind catheter insertion.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The ultrasound phantoms used to educate medical students should not only closely mimic the ultrasound characteristics of human soft tissues but also be inexpensive and easy to manufacture. I have been studying handmade ultrasound phantoms and proposed an ultrasound phantom comprising calcium alginate hydrogel that met these requirements but caused a speckle pattern similar to that observed in ultrasound images of liver. In this study, I show that adding ethanol to the precursors used to fabricate the phantom reduces the speckle pattern. The ultrasound propagation velocity and attenuation coefficient of the phantom were 1561 ± 8 m/s and 0.54 ± 0.18 dB/cm/MHz, respectively (mean ± standard deviation), which are within the ranges of those in human soft tissues (1530-1600 m/s and 0.3-1.0 dB/cm/MHz, respectively). This phantom is easy to fabricate without special equipment, is inexpensive, and is suitable for elementary training on ultrasound diagnosis, operation of ultrasound-guided needles, and blind catheter insertion.
Key concepts: Imaging phantom, Ultrasound, Speckle pattern, Biomedical engineering, Materials science, Attenuation, Attenuation coefficient, Nuclear medicine