Ultrasonic absorption in liver tissue

Leon A. Frizzell, Edwin L. Carstensen, Jeffrey D. Davis

Open publisher page 41 citations

Abstract

Ultrasonic attenuation coefficients were measured in mammalian liver for frequencies ranging from 0.5 to 10 MHz and for a range of sample preparations. Certain preparative procedures were found to greatly increase the low-frequency attenuation coefficient due to the introduction of bubbles into the sample. The low-frequency attenuation was reduced by storage at low temperatures or by pressurization, each caused the bubbles to go into solution, resulting in an attenuation coefficient that was a simple power function of frequency. Absorption coefficients of in vitro and in vivo samples were found to be similar and to show much less dependence on sample preparation than the attenuation measurements. These studies suggest that properties of carefully prepared in vitro samples are indicative of the in vivo properties.

About this research paper

What this paper is about

Ultrasonic attenuation coefficients were measured in mammalian liver for frequencies ranging from 0.5 to 10 MHz and for a range of sample preparations. Certain preparative procedures were found to greatly increase the low-frequency attenuation coefficient due to the introduction of bubbles into the sample. The low-frequency attenuation was reduced by storage at low temperatures or by pressurization, each caused the bubbles to go into solution, resulting in an attenuation coefficient that was a simple power function of frequency. Absorption coefficients of in vitro and in vivo samples were found to be similar and to show much less dependence on sample preparation than the attenuation measurements. These studies suggest that properties of carefully prepared in vitro samples are indicative of the in vivo properties.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Ultrasonic attenuation coefficients were measured in mammalian liver for frequencies ranging from 0.5 to 10 MHz and for a range of sample preparations. Certain preparative procedures were found to greatly increase the low-frequency attenuation coefficient due to the introduction of bubbles into the sample. The low-frequency attenuation was reduced by storage at low temperatures or by pressurization, each caused the bubbles to go into solution, resulting in an attenuation coefficient that was a simple power function of frequency. Absorption coefficients of in vitro and in vivo samples were found to be similar and to show much less dependence on sample preparation than the attenuation measurements. These studies suggest that properties of carefully prepared in vitro samples are indicative of the in vivo properties.

Key concepts: Attenuation, Attenuation coefficient, Materials science, Absorption (acoustics), Ultrasonic attenuation, In vivo, Ultrasonic sensor, Range (aeronautics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Ultrasonic absorption in liver tissue — Research Paper | ScholarLens