Study on On-Site Calibration Method of Stationary Neutron Dosimeter

Jinxu Lv, Ning Lv, Huiping Guo, Mingyan Sun, Kuo Zhao, Wenhui Lv, Wei Zhihao, Qizhan Xiao, Daji Li, Yang Liu

Open publisher page 1 citations

Abstract

Abstract The on-site calibration system of stationary neutron ambient dose equivalent instrument is mainly comprised of a small controllable neutron source and a reference neutron ambient dose equivalent instrument. According to the principle of “relative calibration method”, a small controllable neutron source continuously emits neutrons at the calibration site to construct a neutron radiation field. The calibration factor (NB) can be obtained by comparing the response numbers from two instrument, the instrument to be calibrated and the reference instrument, which are symmetrically placed in the neutron radiation field. In order to complete the transfer of the ambient dose equivalent calibration coefficient of the reference instrument from National Metrology Center (252CfStandard radiation field) to nuclear facility site, the calibration coefficient needs to be corrected, that is, multiplied by the “energy correction coefficient”. Energy correction coefficient includes: (1) “Instrument Energy Response Correction Coefficient” kε for neutron fluence to neutron counting of the instrument, (2) “Conversion Correction Coefficient” kΦ for neutron fluence to neutron ambient dose equivalent. Tests have shown that the ambient dose equivalent rate measurement error of the instrument which have been calibrated but without energy correction was 16.5%, by contrast the measurement error was 2.9% with energy correction. It can be seen that the energy correction is necessary and effective for the measuring instrument of neutron ambient dose equivalent during the on-site calibration process.

About this research paper

What this paper is about

Abstract The on-site calibration system of stationary neutron ambient dose equivalent instrument is mainly comprised of a small controllable neutron source and a reference neutron ambient dose equivalent instrument. According to the principle of “relative calibration method”, a small controllable neutron source continuously emits neutrons at the calibration site to construct a neutron radiation field. The calibration factor (NB) can be obtained by comparing the response numbers from two instrument, the instrument to be calibrated and the reference instrument, which are symmetrically placed in the neutron radiation field. In order to complete the transfer of the ambient dose equivalent calibration coefficient of the reference instrument from National Metrology Center (252CfStandard radiation field) to nuclear facility site, the calibration coefficient needs to be corrected, that is, multiplied by the “energy correction coefficient”. Energy correction coefficient includes: (1) “Instrument Energy Response Correction Coefficient” kε for neutron fluence to neutron counting of the instrument, (2) “Conversion Correction Coefficient” kΦ for neutron fluence to neutron ambient dose equivalent. Tests have shown that the ambient dose equivalent rate measurement error of the instrument which have been calibrated but without energy correction was 16.5%, by contrast the measurement error was 2.9% with energy correction. It can be seen that the energy correction is necessary and effective for the measuring instrument of neutron ambient dose equivalent during the on-site calibration process.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The on-site calibration system of stationary neutron ambient dose equivalent instrument is mainly comprised of a small controllable neutron source and a reference neutron ambient dose equivalent instrument. According to the principle of “relative calibration method”, a small controllable neutron source continuously emits neutrons at the calibration site to construct a neutron radiation field. The calibration factor (NB) can be obtained by comparing the response numbers from two instrument, the instrument to be calibrated and the reference instrument, which are symmetrically placed in the neutron radiation field. In order to complete the transfer of the ambient dose equivalent calibration coefficient of the reference instrument from National Metrology Center (252CfStandard radiation field) to nuclear facility site, the calibration coefficient needs to be corrected, that is, multiplied by the “energy correction coefficient”. Energy correction coefficient includes: (1) “Instrument Energy Response Correction Coefficient” kε for neutron fluence to neutron counting of the instrument, (2) “Conversion Correction Coefficient” kΦ for neutron fluence to neutron ambient dose equivalent. Tests have shown that the ambient dose equivalent rate measurement error of the instrument which have been calibrated but without energy correction was 16.5%, by contrast the measurement error was 2.9% with energy correction. It can be seen that the energy correction is necessary and effective for the measuring instrument of neutron ambient dose equivalent during the on-site calibration process.

Key concepts: Calibration, Neutron, Dosimeter, Equivalent dose, Neutron flux, Neutron temperature, Physics, Metrology