Composite damage track-albedo personnel neutron dosimeter for general use

Carl H. Distenfeld

Open full text 0 citations

Abstract

No known detector or series of detectors in personnel neutron dosimeters have correct dose equivalent energy-dependence. Useful dosimeter performance is assumed by calibrating dosimeters for the exposure spectrum. This method implies that the exposure spectrum will be constant within a given facility or the wearer will not be exposed to different spectra in other areas. Since exposure spectra are known to vary widely a composite damage track-albedo personnel neutron dosimeter was developed to separately respond to the softer and more energetic parts of various spectra. The relationships of the responses of the elements vary with different spectra and are used to convert dosimeter readings to dose equivalent. Measurements indicate that dose equivalent deviation was less than approximately 50 percent for unshielded lucite and steel shielded HPRR spectra, monoenergetic spectra from 4.7 to 15 MeV, a $sup 252$Cf spontaneous neutron spectrum and an AmBe spectrum. Dosimeter sensitivity was similar to present NTA film methods. The composite personnel neutron dosimeter was also tested with calculated spectra by simulating badge response through known energy-dependence of the badge elements. Dose equivalent deviation was less than approximately 20 percent for 19 significantly different assumed spectra. Thus, the experimental and calculational results support adherence to the dose equivalent for common exposure spectra. (auth)

About this research paper

What this paper is about

No known detector or series of detectors in personnel neutron dosimeters have correct dose equivalent energy-dependence. Useful dosimeter performance is assumed by calibrating dosimeters for the exposure spectrum. This method implies that the exposure spectrum will be constant within a given facility or the wearer will not be exposed to different spectra in other areas. Since exposure spectra are known to vary widely a composite damage track-albedo personnel neutron dosimeter was developed to separately respond to the softer and more energetic parts of various spectra. The relationships of the responses of the elements vary with different spectra and are used to convert dosimeter readings to dose equivalent. Measurements indicate that dose equivalent deviation was less than approximately 50 percent for unshielded lucite and steel shielded HPRR spectra, monoenergetic spectra from 4.7 to 15 MeV, a $sup 252$Cf spontaneous neutron spectrum and an AmBe spectrum. Dosimeter sensitivity was similar to present NTA film methods. The composite personnel neutron dosimeter was also tested with calculated spectra by simulating badge response through known energy-dependence of the badge elements. Dose equivalent deviation was less than approximately 20 percent for 19 significantly different assumed spectra. Thus, the experimental and calculational results support adherence to the dose equivalent for common exposure spectra. (auth)

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

No known detector or series of detectors in personnel neutron dosimeters have correct dose equivalent energy-dependence. Useful dosimeter performance is assumed by calibrating dosimeters for the exposure spectrum. This method implies that the exposure spectrum will be constant within a given facility or the wearer will not be exposed to different spectra in other areas. Since exposure spectra are known to vary widely a composite damage track-albedo personnel neutron dosimeter was developed to separately respond to the softer and more energetic parts of various spectra. The relationships of the responses of the elements vary with different spectra and are used to convert dosimeter readings to dose equivalent. Measurements indicate that dose equivalent deviation was less than approximately 50 percent for unshielded lucite and steel shielded HPRR spectra, monoenergetic spectra from 4.7 to 15 MeV, a $sup 252$Cf spontaneous neutron spectrum and an AmBe spectrum. Dosimeter sensitivity was similar to present NTA film methods. The composite personnel neutron dosimeter was also tested with calculated spectra by simulating badge response through known energy-dependence of the badge elements. Dose equivalent deviation was less than approximately 20 percent for 19 significantly different assumed spectra. Thus, the experimental and calculational results support adherence to the dose equivalent for common exposure spectra. (auth)

Key concepts: Dosimeter, Equivalent dose, Neutron, Spectral line, Neutron temperature, Physics, Materials science, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Composite damage track-albedo personnel neutron dosimeter for general use — Research Paper | ScholarLens