2020•The Korean Academy of Oral and Maxillofacial ImplantologyOpen access

Implant Stability Change Measurement of Flaplessly Placed Immediate Implant on Mandibular First Molar

Yang-Yeol Tae, Chan-Ho Jung, Kwan‐Soo Park

Open full text 0 citations

Abstract

This study aims to evaluate the stability change of implants placed immediately after extraction of the mandibular first molar with Resonance Frequency Analysis (RFA). Materials and Methods:For 24 patients, 25 implants with sandblasted, large grit, and acid-etched (SLA) surface were placed with flapless surgery.Implant stability at implant placement and impression taking procedure were measured with Osstell ISQ.The average interval between implant placement and impression taking was 1.82 months, and implants' success rate was 100%.The average follow-up period was 23.8 months. Results:The average RFA value of implants measured in all directions increased by 6.4, and the average RFA value measured in the buccolingual direction increased by 5.9.Moreover, the average RFA value measured in the mesiodistal direction increased by 6.9.There was a statistically significant difference between the buccolingual side' s RFA value and the RFA value in the mesiodistal side at implant placement.There was not a completely linear relationship between the RFA value at implant placement and insertion torque. Conclusion:The change of RFA value can be a useful evaluation method for implant stability of the immediately placed implant after tooth extraction.It may help evaluate the healing of immediately placed implant and determine the appropriate loading time.

Open-access reader

About this research paper

What this paper is about

This study aims to evaluate the stability change of implants placed immediately after extraction of the mandibular first molar with Resonance Frequency Analysis (RFA). Materials and Methods:For 24 patients, 25 implants with sandblasted, large grit, and acid-etched (SLA) surface were placed with flapless surgery.Implant stability at implant placement and impression taking procedure were measured with Osstell ISQ.The average interval between implant placement and impression taking was 1.82 months, and implants' success rate was 100%.The average follow-up period was 23.8 months. Results:The average RFA value of implants measured in all directions increased by 6.4, and the average RFA value measured in the buccolingual direction increased by 5.9.Moreover, the average RFA value measured in the mesiodistal direction increased by 6.9.There was a statistically significant difference between the buccolingual side' s RFA value and the RFA value in the mesiodistal side at implant placement.There was not a completely linear relationship between the RFA value at implant placement and insertion torque. Conclusion:The change of RFA value can be a useful evaluation method for implant stability of the immediately placed implant after tooth extraction.It may help evaluate the healing of immediately placed implant and determine the appropriate loading time.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study aims to evaluate the stability change of implants placed immediately after extraction of the mandibular first molar with Resonance Frequency Analysis (RFA). Materials and Methods:For 24 patients, 25 implants with sandblasted, large grit, and acid-etched (SLA) surface were placed with flapless surgery.Implant stability at implant placement and impression taking procedure were measured with Osstell ISQ.The average interval between implant placement and impression taking was 1.82 months, and implants' success rate was 100%.The average follow-up period was 23.8 months. Results:The average RFA value of implants measured in all directions increased by 6.4, and the average RFA value measured in the buccolingual direction increased by 5.9.Moreover, the average RFA value measured in the mesiodistal direction increased by 6.9.There was a statistically significant difference between the buccolingual side' s RFA value and the RFA value in the mesiodistal side at implant placement.There was not a completely linear relationship between the RFA value at implant placement and insertion torque. Conclusion:The change of RFA value can be a useful evaluation method for implant stability of the immediately placed implant after tooth extraction.It may help evaluate the healing of immediately placed implant and determine the appropriate loading time.

Key concepts: Implant, Resonance frequency analysis, Dentistry, Molar, Dental implant, Medicine, Orthodontics, Initial stability

Related papers

Back to paper searchBrowse research topicsOriginal source
Implant Stability Change Measurement of Flaplessly Placed Immediate Implant on Mandibular First Molar — Research Paper | ScholarLens