Evaluation of NT-proBNP assay performance on electro-chemiluminescence immunoassay system
Xiuming Zhang, Dongmei Wen, Weijia Wang, Fei Li, Lijuan Kan, Haizhong Yan, Minghuan Suo, Nengliang Ouyang
Abstract
Xiuming Zhang, Dongmei Wen, Weijia Wang, Fei Li, Lijuan Kan, Haizhong Yan, Minghuan Suo, Nengliang Ouyang
Abstract
Objective To evaluate analytical performance of NT-proBNP on Electro-Chemiluminescence Immunoassay system.Methods The precision,accuracy,limit of blank ( LoB ),limit of detection (LoD),functional sensitivity (FS),analytical measure range (AMR),maximal dilution rate,clinical reportable range(CRR) and the analytical anti-interference ability of NT-proBNP were evaluated according to EP documents issued by CLSI and related references.The analytical performance data were compared to quality standards declared by the manusfacturers.According to CLSI C28-A2,80 healthy volunteers,aged from 18 to 74, were chosen and divided into 4 groups on average for biological reference intervals verification.Results The within-run CV and total CV were 1.1% -2.2% and 1.5% -2.9% respectively.The deviations from controls distributed by National Center for Clinical Laboratory and affiliated calibrators were 2.7% -5.9% and 2.7% -7.5%,respectively.The results of LoB,LoD and FS were 2.5,7.8 and 8.8 pg/ml,respectively.AMR was 8 -35 126 pg/ml,and the most suitable dilution rate was 1∶ 2,so the CRR was 9 -70 252 pg/ml.428 μmol/L bilirubin,2 g/L haematoglobin and 2 200 FIU chyle didn't interfere with the NT-proBNP assay.Moreover,almost all the data from different age groups were in the range of biological reference intervals declared by the manusfacturers, except one test data (167 pg/ml).Conclusions The analytical performance of NT-proBNP analyzed on Roche Cobas E601 electrochemiluminescence immunoassay system is consistent with the standarls which manufacturers has proclaimed.The establishment of LoD,FS,maximal dilution and CRR for NT-proBNP assay could provide the quality assurance for clinical use and the biological reference intervals declared by manusfacturers could meet the clinical needs. Key words: Natriuretic peptide, brain; Electrochemistry; Luminescence; Immunoassay; Evaluation study
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate analytical performance of NT-proBNP on Electro-Chemiluminescence Immunoassay system.Methods The precision,accuracy,limit of blank ( LoB ),limit of detection (LoD),functional sensitivity (FS),analytical measure range (AMR),maximal dilution rate,clinical reportable range(CRR) and the analytical anti-interference ability of NT-proBNP were evaluated according to EP documents issued by CLSI and related references.The analytical performance data were compared to quality standards declared by the manusfacturers.According to CLSI C28-A2,80 healthy volunteers,aged from 18 to 74, were chosen and divided into 4 groups on average for biological reference intervals verification.Results The within-run CV and total CV were 1.1% -2.2% and 1.5% -2.9% respectively.The deviations from controls distributed by National Center for Clinical Laboratory and affiliated calibrators were 2.7% -5.9% and 2.7% -7.5%,respectively.The results of LoB,LoD and FS were 2.5,7.8 and 8.8 pg/ml,respectively.AMR was 8 -35 126 pg/ml,and the most suitable dilution rate was 1∶ 2,so the CRR was 9 -70 252 pg/ml.428 μmol/L bilirubin,2 g/L haematoglobin and 2 200 FIU chyle didn't interfere with the NT-proBNP assay.Moreover,almost all the data from different age groups were in the range of biological reference intervals declared by the manusfacturers, except one test data (167 pg/ml).Conclusions The analytical performance of NT-proBNP analyzed on Roche Cobas E601 electrochemiluminescence immunoassay system is consistent with the standarls which manufacturers has proclaimed.The establishment of LoD,FS,maximal dilution and CRR for NT-proBNP assay could provide the quality assurance for clinical use and the biological reference intervals declared by manusfacturers could meet the clinical needs. Key words: Natriuretic peptide, brain; Electrochemistry; Luminescence; Immunoassay; Evaluation study
Key concepts: Chemiluminescence, Immunoassay, Detection limit, Chromatography, Electrochemiluminescence, Chemiluminescent immunoassay, Coefficient of variation, Dilution