Multiple-slice spiral CT perfusion imaging of pancreatic cancer

Zhuzhong Cheng, Xu Guohui, Yujie Yang, Ying Cao, Ren He, Xiao-qiu Xi

Open publisher page 0 citations

Abstract

Objective To assess the diagnostic value of multiple-slice spiral CT (MSCT) perfusion imaging technique in pancreatic cancer by measuring and comparing the dynamical characteristics of blood flow between normal pancreas and pancreatic cancer. Methods The CT perfusion imaging were obtained using Siemens Somatoma MSCT scanner in 44 patients with normal pancreas tissue and 18 patients with pancreatic cancer. The mean blood flow (BF),blood volume (BV), time to start (Trs), time to peak (TIP), permeability and patlak blood volume (pBV) were measured and statistically analyzed by using Siemens Body peHusion software package. Results The mean BF, BV, Trs, TIP, permeability and pBV of normal pancreas were: (90.60±29.25) ml·100 ml-1·min-1, (190.35±43.8) ml/L, (205.3±160.2) s, (1403.5±334.0)s, (99.47±49.9) 0.5 ml·100 ml-1·min-1, (157.8±52.5) ml/L, respectively. The mean BF, BV, TTS, TrP, per-meability and pBV of pancreatic cancer were (22.9±10. 63) ml·100 ml-1·min-1, (52.38±18.08) ml/L, (194.3±76.0) s, (1549.5± 308.5)s, (115.25±33.55) 0.5 ml·100 ml-1·min-1, (83.16±41.45) ml/L respectively. The mean BF, BV, pBV and permeability between normal pancreas and pancreatic carcinoma were statistically significant (P 0.05). Conclusion There are significant differences between perfusion values of pancreatic carcinoma and normal pancreatic tissue, and MSCT perfusion imaging is helpful in diagnosing pancreatic carcinoma. Key words: Pancreatic neoplasm;  Tomography, X-ray computed;  Perfusion

About this research paper

What this paper is about

Objective To assess the diagnostic value of multiple-slice spiral CT (MSCT) perfusion imaging technique in pancreatic cancer by measuring and comparing the dynamical characteristics of blood flow between normal pancreas and pancreatic cancer. Methods The CT perfusion imaging were obtained using Siemens Somatoma MSCT scanner in 44 patients with normal pancreas tissue and 18 patients with pancreatic cancer. The mean blood flow (BF),blood volume (BV), time to start (Trs), time to peak (TIP), permeability and patlak blood volume (pBV) were measured and statistically analyzed by using Siemens Body peHusion software package. Results The mean BF, BV, Trs, TIP, permeability and pBV of normal pancreas were: (90.60±29.25) ml·100 ml-1·min-1, (190.35±43.8) ml/L, (205.3±160.2) s, (1403.5±334.0)s, (99.47±49.9) 0.5 ml·100 ml-1·min-1, (157.8±52.5) ml/L, respectively. The mean BF, BV, TTS, TrP, per-meability and pBV of pancreatic cancer were (22.9±10. 63) ml·100 ml-1·min-1, (52.38±18.08) ml/L, (194.3±76.0) s, (1549.5± 308.5)s, (115.25±33.55) 0.5 ml·100 ml-1·min-1, (83.16±41.45) ml/L respectively. The mean BF, BV, pBV and permeability between normal pancreas and pancreatic carcinoma were statistically significant (P 0.05). Conclusion There are significant differences between perfusion values of pancreatic carcinoma and normal pancreatic tissue, and MSCT perfusion imaging is helpful in diagnosing pancreatic carcinoma. Key words: Pancreatic neoplasm;  Tomography, X-ray computed;  Perfusion

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To assess the diagnostic value of multiple-slice spiral CT (MSCT) perfusion imaging technique in pancreatic cancer by measuring and comparing the dynamical characteristics of blood flow between normal pancreas and pancreatic cancer. Methods The CT perfusion imaging were obtained using Siemens Somatoma MSCT scanner in 44 patients with normal pancreas tissue and 18 patients with pancreatic cancer. The mean blood flow (BF),blood volume (BV), time to start (Trs), time to peak (TIP), permeability and patlak blood volume (pBV) were measured and statistically analyzed by using Siemens Body peHusion software package. Results The mean BF, BV, Trs, TIP, permeability and pBV of normal pancreas were: (90.60±29.25) ml·100 ml-1·min-1, (190.35±43.8) ml/L, (205.3±160.2) s, (1403.5±334.0)s, (99.47±49.9) 0.5 ml·100 ml-1·min-1, (157.8±52.5) ml/L, respectively. The mean BF, BV, TTS, TrP, per-meability and pBV of pancreatic cancer were (22.9±10. 63) ml·100 ml-1·min-1, (52.38±18.08) ml/L, (194.3±76.0) s, (1549.5± 308.5)s, (115.25±33.55) 0.5 ml·100 ml-1·min-1, (83.16±41.45) ml/L respectively. The mean BF, BV, pBV and permeability between normal pancreas and pancreatic carcinoma were statistically significant (P 0.05). Conclusion There are significant differences between perfusion values of pancreatic carcinoma and normal pancreatic tissue, and MSCT perfusion imaging is helpful in diagnosing pancreatic carcinoma. Key words: Pancreatic neoplasm;  Tomography, X-ray computed;  Perfusion

Key concepts: Pancreatic cancer, Medicine, Perfusion, Nuclear medicine, Pancreas, Blood volume, Perfusion scanning, Blood flow

Related papers

Back to paper searchBrowse research topicsOriginal source
Multiple-slice spiral CT perfusion imaging of pancreatic cancer — Research Paper | ScholarLens