Determination of ginsenoside Rg1 and Re in Tongru granules by HPLC
Yan Li, Hongjie Cheng, Keming Li
Abstract
Yan Li, Hongjie Cheng, Keming Li
Abstract
Objective To establish a rapid and efficient method for the simultaneous determination of ginsenoside Rg1 and ginsenoside Re in Tongru granules by HPLC. Methods The HPLC analysis was carried out with Agilent ZORBAX SB-C18 and acetonitrile-0.1% phosphoric acid(15:85, V/V) as mobile phase, the flow rate was 1.0 ml/min, the column temperature was 30 ℃, injection volume was 10 μl, and the detection wavelength was 203 nm. Results The Rg1 solution of ginsenoside showed a good linear relation between 0.136-2.040 μg (r2=0.999 9). The ginsenoside Re solution presented a good linear relationship (r2=0.999 8) between 0.066-0.990 μg, with the average addition recovery of 99.3% and 99.1%, and the relative standard deviation of 0.84% and 0.75%(n=6), respectively. Conclusions The method is highly specific, sensitive, reproducible, simple and efficient which can be used for quality control of Tongru Granules. Key words: Ginsenoside Rg1; Ginsenoside Re; High performance liquid chromatography; Tongru granules; Assay (TCD); Quality control
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To establish a rapid and efficient method for the simultaneous determination of ginsenoside Rg1 and ginsenoside Re in Tongru granules by HPLC. Methods The HPLC analysis was carried out with Agilent ZORBAX SB-C18 and acetonitrile-0.1% phosphoric acid(15:85, V/V) as mobile phase, the flow rate was 1.0 ml/min, the column temperature was 30 ℃, injection volume was 10 μl, and the detection wavelength was 203 nm. Results The Rg1 solution of ginsenoside showed a good linear relation between 0.136-2.040 μg (r2=0.999 9). The ginsenoside Re solution presented a good linear relationship (r2=0.999 8) between 0.066-0.990 μg, with the average addition recovery of 99.3% and 99.1%, and the relative standard deviation of 0.84% and 0.75%(n=6), respectively. Conclusions The method is highly specific, sensitive, reproducible, simple and efficient which can be used for quality control of Tongru Granules. Key words: Ginsenoside Rg1; Ginsenoside Re; High performance liquid chromatography; Tongru granules; Assay (TCD); Quality control
Key concepts: Ginsenoside Rg1, Chromatography, Phosphoric acid, High-performance liquid chromatography, Chemistry, Relative standard deviation, Ginsenoside, Linear relationship