Determination of Ginsenoside Rg1 and Re in Keshu Capsule by HPLC
Ming Zeng
Abstract
Ming Zeng
Abstract
Objective To set up a method to determine content of ginsenoside Rg1 and Re in Keshu capsule. Methods It was tested by HPLC with zorbax SB-C18 column,mobile phase acetonitrile/purified water 20:80,detection wavelength at 205 nm. Results The linear range of ginsenoside Rg1 and Re were both 100-6 000 ng,r= 0.999 9,showed good relationship,and the average recovery rate were 99.41% and 100.84%,respectively. Conclusion This method is simple and accurate for the content determination of ginsenoside Rg1 and Re in Keshu capsule.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To set up a method to determine content of ginsenoside Rg1 and Re in Keshu capsule. Methods It was tested by HPLC with zorbax SB-C18 column,mobile phase acetonitrile/purified water 20:80,detection wavelength at 205 nm. Results The linear range of ginsenoside Rg1 and Re were both 100-6 000 ng,r= 0.999 9,showed good relationship,and the average recovery rate were 99.41% and 100.84%,respectively. Conclusion This method is simple and accurate for the content determination of ginsenoside Rg1 and Re in Keshu capsule.
Key concepts: Ginsenoside Rg1, Capsule, Chromatography, High-performance liquid chromatography, Chemistry, Linear range, Ginsenoside, Recovery rate