2014•Zhonghua chaosheng yingxiangxue zazhiRequires access

Transcatheter closure of atrial septal defect under the guidance of two-dimensional transthoracic echocardiography

Kunjing Pang, Hao Wang, Hong Meng, Xing Zhao

Open publisher page 1 citations

Abstract

Objective To explore the feasibility of transcatheter closure of atrial septal defect (ASD) under the guidance of two-dimensional transthoracic echocardiography (2D-TTE).Methods The study involved 40 patients diagnosed as ASD by TTE.The mean age of the patients was (7.25 ± 3.96)years,and the mean weights was (22.32 ± 8.30)kg.The mean diameters of ASD was (11.37 ± 3.61)mm.The patients underwent local or basal anesthesia.The transcatheter closure of ASD were performed under the guidance of 2D-TTE.The patients underwent follow-up echocardiography at one and three months after surgery.Results Closure devices were successfully implanted in 37 patients under 2D-TTE guidance.The procedure was simply and safe.In 3 patients,the procedure was monitored by transesophageal echocardiography (TEE) after tracheal intubation,instead of 2D-TTE,because the 2D-TTE images were not clear.During the followup,no severe complication such as valvular injury,pericardial effusion,residual shunt,and peripheral vascular injury occurred.Conclusions Transcatheter closure of ASD under 2D-TTE guidance provides a feasibility method which not only overcome the damage of radiation,but also avoided pains and risks of TEE.The procedure has a broad clinic prospects. Key words: Echocardiography; Atrial septal defect; Transcatheter closure

About this research paper

What this paper is about

Objective To explore the feasibility of transcatheter closure of atrial septal defect (ASD) under the guidance of two-dimensional transthoracic echocardiography (2D-TTE).Methods The study involved 40 patients diagnosed as ASD by TTE.The mean age of the patients was (7.25 ± 3.96)years,and the mean weights was (22.32 ± 8.30)kg.The mean diameters of ASD was (11.37 ± 3.61)mm.The patients underwent local or basal anesthesia.The transcatheter closure of ASD were performed under the guidance of 2D-TTE.The patients underwent follow-up echocardiography at one and three months after surgery.Results Closure devices were successfully implanted in 37 patients under 2D-TTE guidance.The procedure was simply and safe.In 3 patients,the procedure was monitored by transesophageal echocardiography (TEE) after tracheal intubation,instead of 2D-TTE,because the 2D-TTE images were not clear.During the followup,no severe complication such as valvular injury,pericardial effusion,residual shunt,and peripheral vascular injury occurred.Conclusions Transcatheter closure of ASD under 2D-TTE guidance provides a feasibility method which not only overcome the damage of radiation,but also avoided pains and risks of TEE.The procedure has a broad clinic prospects. Key words: Echocardiography; Atrial septal defect; Transcatheter closure

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To explore the feasibility of transcatheter closure of atrial septal defect (ASD) under the guidance of two-dimensional transthoracic echocardiography (2D-TTE).Methods The study involved 40 patients diagnosed as ASD by TTE.The mean age of the patients was (7.25 ± 3.96)years,and the mean weights was (22.32 ± 8.30)kg.The mean diameters of ASD was (11.37 ± 3.61)mm.The patients underwent local or basal anesthesia.The transcatheter closure of ASD were performed under the guidance of 2D-TTE.The patients underwent follow-up echocardiography at one and three months after surgery.Results Closure devices were successfully implanted in 37 patients under 2D-TTE guidance.The procedure was simply and safe.In 3 patients,the procedure was monitored by transesophageal echocardiography (TEE) after tracheal intubation,instead of 2D-TTE,because the 2D-TTE images were not clear.During the followup,no severe complication such as valvular injury,pericardial effusion,residual shunt,and peripheral vascular injury occurred.Conclusions Transcatheter closure of ASD under 2D-TTE guidance provides a feasibility method which not only overcome the damage of radiation,but also avoided pains and risks of TEE.The procedure has a broad clinic prospects. Key words: Echocardiography; Atrial septal defect; Transcatheter closure

Key concepts: Medicine, Pericardial effusion, Shunt (medical), Cardiology, Complication, Internal medicine, Effusion, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Transcatheter closure of atrial septal defect under the guidance of two-dimensional transthoracic echocardiography — Research Paper | ScholarLens