2009•Zhonghua chaosheng yingxiangxue zazhiRequires access

Intravascular ultrasound study on carotid stent and balloon angioplasty of swines

Yaguo Li, Shu-Wei Huang, Shou-feng Jiang, Bozhong Wang

Open publisher page 0 citations

Abstract

Objective To investigate the mechanism of restenosis after carotid stent and balloon angioplasty for the Guangxi swines by intravascular ultrasound(IVUS). Methods Twelve Guangxi swines fed by a high cholesterol diet were randomly divided into two groups. Seven stents were implanted in the left carotid artery of six swines in the first group, and balloon angioplasty was performed in the left carotid artery of swines in the other group. Digital subtraction angiography(DSA) and IVUS were conducted respectively before and after the intervention and in the 13th week. Results IVUS found that the percentage of area stenosis in stent group was (18.31±7.79) % and in balloon group (37.28±7.89) % in the 13th week. The percentage of area restenosis in stent was obviously related to neointimal hyperplasia (r = 0.897, P<0.05), the percentage of area restenosis due to balloon angioplasty was markedly related to area decrease of external elastic lamina (r = 0.856, P<0.05). Conclusions The restenosis in stent was related to intimal hyperplasia of blood vessel,and restenosis after balloon angioplasty had some connection with area decrease of external elastic lamina. Key words: Endosonography; Carotid arteries ; Stent; Angioplasty,balloon

About this research paper

What this paper is about

Objective To investigate the mechanism of restenosis after carotid stent and balloon angioplasty for the Guangxi swines by intravascular ultrasound(IVUS). Methods Twelve Guangxi swines fed by a high cholesterol diet were randomly divided into two groups. Seven stents were implanted in the left carotid artery of six swines in the first group, and balloon angioplasty was performed in the left carotid artery of swines in the other group. Digital subtraction angiography(DSA) and IVUS were conducted respectively before and after the intervention and in the 13th week. Results IVUS found that the percentage of area stenosis in stent group was (18.31±7.79) % and in balloon group (37.28±7.89) % in the 13th week. The percentage of area restenosis in stent was obviously related to neointimal hyperplasia (r = 0.897, P<0.05), the percentage of area restenosis due to balloon angioplasty was markedly related to area decrease of external elastic lamina (r = 0.856, P<0.05). Conclusions The restenosis in stent was related to intimal hyperplasia of blood vessel,and restenosis after balloon angioplasty had some connection with area decrease of external elastic lamina. Key words: Endosonography; Carotid arteries ; Stent; Angioplasty,balloon

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the mechanism of restenosis after carotid stent and balloon angioplasty for the Guangxi swines by intravascular ultrasound(IVUS). Methods Twelve Guangxi swines fed by a high cholesterol diet were randomly divided into two groups. Seven stents were implanted in the left carotid artery of six swines in the first group, and balloon angioplasty was performed in the left carotid artery of swines in the other group. Digital subtraction angiography(DSA) and IVUS were conducted respectively before and after the intervention and in the 13th week. Results IVUS found that the percentage of area stenosis in stent group was (18.31±7.79) % and in balloon group (37.28±7.89) % in the 13th week. The percentage of area restenosis in stent was obviously related to neointimal hyperplasia (r = 0.897, P<0.05), the percentage of area restenosis due to balloon angioplasty was markedly related to area decrease of external elastic lamina (r = 0.856, P<0.05). Conclusions The restenosis in stent was related to intimal hyperplasia of blood vessel,and restenosis after balloon angioplasty had some connection with area decrease of external elastic lamina. Key words: Endosonography; Carotid arteries ; Stent; Angioplasty,balloon

Key concepts: Medicine, Restenosis, Intravascular ultrasound, Angioplasty, Balloon, Stent, Internal elastic lamina, Stenosis

Related papers

Back to paper searchBrowse research topicsOriginal source
Intravascular ultrasound study on carotid stent and balloon angioplasty of swines — Research Paper | ScholarLens