2007•Modern Medical JournalRequires access

Development of a porcine restenosis model of coronary artery and evaluation by intravascular ultrasound

Wang Ji-hui

Open publisher page 0 citations

Abstract

Objective To develop a porcine restenosis model of coronary artery,and to evaluate it by intravascular ultrasound(IVUS).Methods Nine bare metal stents were implanted into left anterior descendings(LADs) of nine swines [stent/vessel=(1.1-1.2)/1.0].Then 28 days later,the in-stent restenosis were measured by quantity coronary angiography(QCA),IVUS and histomorphology respectively.Results After 28 days five swines were undergone re-examination.QCA showed that the post-stenting vessel diameter increased markedly compared with base vessel diameter [(2.90±0.26)mm vs (2.52±0.31)mm,P=0.001].The follow-up vessel diameter [(1.20±0.77)mm] was diminished markedly compared with the post-stenting vessel diameter(P=0.002),and the percentage of diameter stenosis was(60.2±23.5)%,while the in-stent restenosis rate was 60%.Histomorphometric results showed that the lumen area was diminished remarkably compared with the in-stent areas [(1.29±1.02) mm2 vs(6.04±1.21) mm2,P0.01],and the average percent area of stenosis was(77.9±19.7)%.IVUS analysis yielded similar results [the lumen area(1.67±1.17)mm2 vs(5.85±0.94) mm2,P0.01];the average percent area of stenosis(71.0±23.3)%.Respective area of in-stent,lumen,neointimal and the average percent area of stenosis acquired by IVUS analysis were consistent with histomorphometric results(P0.05).Conclusions A porcine restenosis model of coronary artery was successfully produced in which in-stent restenosis can be evaluated by IVUS in a porcine restenosis model.

About this research paper

What this paper is about

Objective To develop a porcine restenosis model of coronary artery,and to evaluate it by intravascular ultrasound(IVUS).Methods Nine bare metal stents were implanted into left anterior descendings(LADs) of nine swines [stent/vessel=(1.1-1.2)/1.0].Then 28 days later,the in-stent restenosis were measured by quantity coronary angiography(QCA),IVUS and histomorphology respectively.Results After 28 days five swines were undergone re-examination.QCA showed that the post-stenting vessel diameter increased markedly compared with base vessel diameter [(2.90±0.26)mm vs (2.52±0.31)mm,P=0.001].The follow-up vessel diameter [(1.20±0.77)mm] was diminished markedly compared with the post-stenting vessel diameter(P=0.002),and the percentage of diameter stenosis was(60.2±23.5)%,while the in-stent restenosis rate was 60%.Histomorphometric results showed that the lumen area was diminished remarkably compared with the in-stent areas [(1.29±1.02) mm2 vs(6.04±1.21) mm2,P0.01],and the average percent area of stenosis was(77.9±19.7)%.IVUS analysis yielded similar results [the lumen area(1.67±1.17)mm2 vs(5.85±0.94) mm2,P0.01];the average percent area of stenosis(71.0±23.3)%.Respective area of in-stent,lumen,neointimal and the average percent area of stenosis acquired by IVUS analysis were consistent with histomorphometric results(P0.05).Conclusions A porcine restenosis model of coronary artery was successfully produced in which in-stent restenosis can be evaluated by IVUS in a porcine restenosis model.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a porcine restenosis model of coronary artery,and to evaluate it by intravascular ultrasound(IVUS).Methods Nine bare metal stents were implanted into left anterior descendings(LADs) of nine swines [stent/vessel=(1.1-1.2)/1.0].Then 28 days later,the in-stent restenosis were measured by quantity coronary angiography(QCA),IVUS and histomorphology respectively.Results After 28 days five swines were undergone re-examination.QCA showed that the post-stenting vessel diameter increased markedly compared with base vessel diameter [(2.90±0.26)mm vs (2.52±0.31)mm,P=0.001].The follow-up vessel diameter [(1.20±0.77)mm] was diminished markedly compared with the post-stenting vessel diameter(P=0.002),and the percentage of diameter stenosis was(60.2±23.5)%,while the in-stent restenosis rate was 60%.Histomorphometric results showed that the lumen area was diminished remarkably compared with the in-stent areas [(1.29±1.02) mm2 vs(6.04±1.21) mm2,P0.01],and the average percent area of stenosis was(77.9±19.7)%.IVUS analysis yielded similar results [the lumen area(1.67±1.17)mm2 vs(5.85±0.94) mm2,P0.01];the average percent area of stenosis(71.0±23.3)%.Respective area of in-stent,lumen,neointimal and the average percent area of stenosis acquired by IVUS analysis were consistent with histomorphometric results(P0.05).Conclusions A porcine restenosis model of coronary artery was successfully produced in which in-stent restenosis can be evaluated by IVUS in a porcine restenosis model.

Key concepts: Restenosis, Intravascular ultrasound, Medicine, Lumen (anatomy), Stenosis, Stent, Artery, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of a porcine restenosis model of coronary artery and evaluation by intravascular ultrasound — Research Paper | ScholarLens