1999•Catheterization and Cardiovascular InterventionsRequires access

Intravascular ultrasound-guided balloon angioplasty for treatment of in-stent restenosis

Tsunemori Sakamoto, Takahiko Kawarabayashi, Haruyuki Taguchi, Atsushi Tanaka, Yukio Nishida, Kenei Shimada, Junichi Yoshikawa

Open publisher page 7 citations

Abstract

We investigated the usefulness of intravascular ultrasound (IVUS)-guided balloon angioplasty for in-stent restenosis in 37 lesions of 34 consecutive patients. We divided these patients into two groups: a group in which the balloon size was determined by quantitative coronary angiography (QCA group; 17 patients, 19 lesions) and a group in which the balloon size was determined by IVUS (IVUS group; 17 patients, 18 lesions). We compared short-term and 6-month outcomes for these groups. In the IVUS group, we used a balloon of a size equal to 95% of the media-to-media diameter at the distal to the stent, as determined by IVUS. No significant differences were observed in patient or lesion characteristics between the two groups. The clinical success rate was 100% in both groups, and no clinical events were observed in either of the groups. The balloon/artery ratio was larger in the IVUS group than in the QCA group (1.33 +/- 0.35 vs. 1.16 +/- 0.13, P < 0.05), and the recurrent restenosis rate was lower (17% vs. 53%, P < 0.05). These results suggest that repeat balloon angioplasty using a balloon size determined by IVUS is useful for in-stent restenosis. Cathet. Cardiovasc. Intervent. 47:298-303, 1999.

About this research paper

What this paper is about

We investigated the usefulness of intravascular ultrasound (IVUS)-guided balloon angioplasty for in-stent restenosis in 37 lesions of 34 consecutive patients. We divided these patients into two groups: a group in which the balloon size was determined by quantitative coronary angiography (QCA group; 17 patients, 19 lesions) and a group in which the balloon size was determined by IVUS (IVUS group; 17 patients, 18 lesions). We compared short-term and 6-month outcomes for these groups. In the IVUS group, we used a balloon of a size equal to 95% of the media-to-media diameter at the distal to the stent, as determined by IVUS. No significant differences were observed in patient or lesion characteristics between the two groups. The clinical success rate was 100% in both groups, and no clinical events were observed in either of the groups. The balloon/artery ratio was larger in the IVUS group than in the QCA group (1.33 +/- 0.35 vs. 1.16 +/- 0.13, P < 0.05), and the recurrent restenosis rate was lower (17% vs. 53%, P < 0.05). These results suggest that repeat balloon angioplasty using a balloon size determined by IVUS is useful for in-stent restenosis. Cathet. Cardiovasc. Intervent. 47:298-303, 1999.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We investigated the usefulness of intravascular ultrasound (IVUS)-guided balloon angioplasty for in-stent restenosis in 37 lesions of 34 consecutive patients. We divided these patients into two groups: a group in which the balloon size was determined by quantitative coronary angiography (QCA group; 17 patients, 19 lesions) and a group in which the balloon size was determined by IVUS (IVUS group; 17 patients, 18 lesions). We compared short-term and 6-month outcomes for these groups. In the IVUS group, we used a balloon of a size equal to 95% of the media-to-media diameter at the distal to the stent, as determined by IVUS. No significant differences were observed in patient or lesion characteristics between the two groups. The clinical success rate was 100% in both groups, and no clinical events were observed in either of the groups. The balloon/artery ratio was larger in the IVUS group than in the QCA group (1.33 +/- 0.35 vs. 1.16 +/- 0.13, P < 0.05), and the recurrent restenosis rate was lower (17% vs. 53%, P < 0.05). These results suggest that repeat balloon angioplasty using a balloon size determined by IVUS is useful for in-stent restenosis. Cathet. Cardiovasc. Intervent. 47:298-303, 1999.

Key concepts: Medicine, Intravascular ultrasound, Restenosis, Balloon, Angioplasty, Radiology, Stent, Angiography

Related papers

Back to paper searchBrowse research topicsOriginal source
Intravascular ultrasound-guided balloon angioplasty for treatment of in-stent restenosis — Research Paper | ScholarLens