Performance verification and evaluation of 4 domestic chemiluminescence systems on 8 tumor markers

Yan Shi, Yancai Wei, Weiling Zheng, Wei Jia-ling, Miaoli Song, Gengchao Zhu, Xun Lu

Open publisher page 0 citations

Abstract

Objective To validate the performance of 4 domestic chemiluminescence immunoassay (CLIA) systems on 8 tumor markers quantitative assay kits. Methods Four domestic CLIA systems were randomly marked as A, B, C, D and 8 tumor markers, including carbohydrate antigen (CA)125, CA15-3, CA19-9, ferritin (Fer), alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), prostate-specific antigen (PSA) and free PSA (fPSA) were determined. According to the standard of Clinical and Laboratory Standards Institute (CLSI), the precision, methodological comparison and analytical measure range of 4 systems were validated. Clinical serum samples were obtained from patients in Suzhou Hospital. According to the CLSI EP9-A3 protocol, imported equipment was used as the reference system. The biases of medical decision points were assumed, and Pearson correlation analysis and Spearman correlation analysis were used to analyze the data. Results The precision verification of CA125 and PSA on A, CA125 and AFP on B, CA125, CEA, AFP and PSA on C, and all 8 tumor markers on D could meet the laboratory quality control requirements. The correlations of the test results between A-D and the imported equipment were significant (all P<0.05) with the correlation coefficients 0.79-0.99, 0.47-0.99, 0.90-0.98 and 0.78-1.00, respectively, and the number of acceptable tests at the level of medical decision was 5, 2, 5, 4. All tests were certified to meet the analytical measure range validation. Conclusions The detection performance of 4 domestic CLIA systems for all 8 tumor markers are different. The performance of domestic CLIA systems should be tested when choosing one that can meet laboratory quality control requirements. Key words: Chemiluminescent measurements; Immunoassay; Tumor markers, biological

About this research paper

What this paper is about

Objective To validate the performance of 4 domestic chemiluminescence immunoassay (CLIA) systems on 8 tumor markers quantitative assay kits. Methods Four domestic CLIA systems were randomly marked as A, B, C, D and 8 tumor markers, including carbohydrate antigen (CA)125, CA15-3, CA19-9, ferritin (Fer), alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), prostate-specific antigen (PSA) and free PSA (fPSA) were determined. According to the standard of Clinical and Laboratory Standards Institute (CLSI), the precision, methodological comparison and analytical measure range of 4 systems were validated. Clinical serum samples were obtained from patients in Suzhou Hospital. According to the CLSI EP9-A3 protocol, imported equipment was used as the reference system. The biases of medical decision points were assumed, and Pearson correlation analysis and Spearman correlation analysis were used to analyze the data. Results The precision verification of CA125 and PSA on A, CA125 and AFP on B, CA125, CEA, AFP and PSA on C, and all 8 tumor markers on D could meet the laboratory quality control requirements. The correlations of the test results between A-D and the imported equipment were significant (all P<0.05) with the correlation coefficients 0.79-0.99, 0.47-0.99, 0.90-0.98 and 0.78-1.00, respectively, and the number of acceptable tests at the level of medical decision was 5, 2, 5, 4. All tests were certified to meet the analytical measure range validation. Conclusions The detection performance of 4 domestic CLIA systems for all 8 tumor markers are different. The performance of domestic CLIA systems should be tested when choosing one that can meet laboratory quality control requirements. Key words: Chemiluminescent measurements; Immunoassay; Tumor markers, biological

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To validate the performance of 4 domestic chemiluminescence immunoassay (CLIA) systems on 8 tumor markers quantitative assay kits. Methods Four domestic CLIA systems were randomly marked as A, B, C, D and 8 tumor markers, including carbohydrate antigen (CA)125, CA15-3, CA19-9, ferritin (Fer), alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), prostate-specific antigen (PSA) and free PSA (fPSA) were determined. According to the standard of Clinical and Laboratory Standards Institute (CLSI), the precision, methodological comparison and analytical measure range of 4 systems were validated. Clinical serum samples were obtained from patients in Suzhou Hospital. According to the CLSI EP9-A3 protocol, imported equipment was used as the reference system. The biases of medical decision points were assumed, and Pearson correlation analysis and Spearman correlation analysis were used to analyze the data. Results The precision verification of CA125 and PSA on A, CA125 and AFP on B, CA125, CEA, AFP and PSA on C, and all 8 tumor markers on D could meet the laboratory quality control requirements. The correlations of the test results between A-D and the imported equipment were significant (all P<0.05) with the correlation coefficients 0.79-0.99, 0.47-0.99, 0.90-0.98 and 0.78-1.00, respectively, and the number of acceptable tests at the level of medical decision was 5, 2, 5, 4. All tests were certified to meet the analytical measure range validation. Conclusions The detection performance of 4 domestic CLIA systems for all 8 tumor markers are different. The performance of domestic CLIA systems should be tested when choosing one that can meet laboratory quality control requirements. Key words: Chemiluminescent measurements; Immunoassay; Tumor markers, biological

Key concepts: Carcinoembryonic antigen, External quality assessment, Immunoassay, Medicine, Prostate-specific antigen, Chemiluminescent immunoassay, Spearman's rank correlation coefficient, Oncology

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance verification and evaluation of 4 domestic chemiluminescence systems on 8 tumor markers — Research Paper | ScholarLens