Comparison of the SLIPA mask airway and endotracheal intubation in the cesarean section operation under general anesthesia
赵金玉, 张绪东, 韩萍, 楚艳艳
Abstract
赵金玉, 张绪东, 韩萍, 楚艳艳
Abstract
Objective To observe the safety and efficacy of the SLIPA mask airway in the cesarean section operation under general anesthesia.Methods Fifty single birth pregnant women who underwent cesarean operation under general anesthesia were randomized into 2 groups.SLIPA mask group(group S,25 cases)and endotracheal intubation(ETT)group(group T,25 cases).Mean arterial pressure(MAP),heart rate(HR),partial pressure of carbon dioxide in end expired gas(P_(ET)CO_2),peak airway pressure(Paw)were measured before induction of anesthesia,just before intubation,2min after intubation,just before extubation,2 min after extubation.Bucking,style,reflow,vomiting,aspiration were observed at inmbation or SLIPA mask airway insertion,before and after extubation and intraoperative.Umbilical arteries and veins blood were collected at delivery for the blood gas analysis.All delivery times,operation time and Apgar scores at 1,5 min were recorded.Results The successful rate ofthe first time intubation was 100% in group S,there was 2 cases by the second time intubation in group T.There Was 3 cases with gently air leak,but no influence on respiratory management.After intubation and extubation,MAP and HR increased significantly in group T (P 0.05).Conclusion There is less adverse effects of SLIPA mask airway than ETT under general anesthesia in the cesarean section operation,SLIPA mask airway is safe and efficacious. Key words: Cesarean section; Catheterization,peripheral; Pulmonary ventilation
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To observe the safety and efficacy of the SLIPA mask airway in the cesarean section operation under general anesthesia.Methods Fifty single birth pregnant women who underwent cesarean operation under general anesthesia were randomized into 2 groups.SLIPA mask group(group S,25 cases)and endotracheal intubation(ETT)group(group T,25 cases).Mean arterial pressure(MAP),heart rate(HR),partial pressure of carbon dioxide in end expired gas(P_(ET)CO_2),peak airway pressure(Paw)were measured before induction of anesthesia,just before intubation,2min after intubation,just before extubation,2 min after extubation.Bucking,style,reflow,vomiting,aspiration were observed at inmbation or SLIPA mask airway insertion,before and after extubation and intraoperative.Umbilical arteries and veins blood were collected at delivery for the blood gas analysis.All delivery times,operation time and Apgar scores at 1,5 min were recorded.Results The successful rate ofthe first time intubation was 100% in group S,there was 2 cases by the second time intubation in group T.There Was 3 cases with gently air leak,but no influence on respiratory management.After intubation and extubation,MAP and HR increased significantly in group T (P 0.05).Conclusion There is less adverse effects of SLIPA mask airway than ETT under general anesthesia in the cesarean section operation,SLIPA mask airway is safe and efficacious. Key words: Cesarean section; Catheterization,peripheral; Pulmonary ventilation
Key concepts: Medicine, Anesthesia, Intubation, Airway, Tracheal intubation, Airway management, Ventilation (architecture), Blood pressure