2020•BMC OphthalmologyOpen access

Evaluation of posterior capsule opacification of the Alcon Clareon IOL vs the Alcon Acrysof IOL using a human capsular bag model

Anna Hillenmayer, Christian Maximilian Wertheimer, Stefan A. Kassumeh, Annabel von Studnitz, Nikolaus Luft, Andreas Ohlmann, Siegfried Georg Priglinger, Wolfgang Johann Mayer

Open full text 18 citations

Abstract

BACKGROUND: Posterior capsule opacification (PCO) after cataract surgery is influenced by intraocular lens (IOL) design and material. The following is an ex vivo comparison of PCO between the Clareon vs. the AcrySof IOL in human capsular bags. METHODS: Twenty cadaver capsular bags from 10 human donors were used, with the novel hydrophobic IOL (Clareon, CNA0T0) being implanted in one eye and the other eye of the same donor receiving the AcrySof IOL (SN60WF) following phacoemulsification cataract surgery. Five capsular bags of 3 donors served as controls without IOL. Cellular growth of lens epithelial cells was photo-documented daily. The primary endpoint was the time until full coverage of the posterior capsule by cells. Furthermore, immunofluorescence staining of capsular bags for the fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were performed. RESULTS: The new Clareon IOL did not show any disadvantages in terms of days until full cell coverage of the posterior capsule in comparison to the AcrySof (p > 0.99). Both, the Clareon (p = 0.01, 14.8 days) and the AcrySof IOL (p = 0.005, 15.7 days) showed a slower PCO development in comparison to the control (8.6 days). The fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were equally distributed between the two IOLs and differed from the control. CONCLUSIONS: A comparable performance has been found in the ex vivo formation of PCO between the two IOLs. Long-term clinical studies are necessary to reach final conclusions.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Posterior capsule opacification (PCO) after cataract surgery is influenced by intraocular lens (IOL) design and material. The following is an ex vivo comparison of PCO between the Clareon vs. the AcrySof IOL in human capsular bags. METHODS: Twenty cadaver capsular bags from 10 human donors were used, with the novel hydrophobic IOL (Clareon, CNA0T0) being implanted in one eye and the other eye of the same donor receiving the AcrySof IOL (SN60WF) following phacoemulsification cataract surgery. Five capsular bags of 3 donors served as controls without IOL. Cellular growth of lens epithelial cells was photo-documented daily. The primary endpoint was the time until full coverage of the posterior capsule by cells. Furthermore, immunofluorescence staining of capsular bags for the fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were performed. RESULTS: The new Clareon IOL did not show any disadvantages in terms of days until full cell coverage of the posterior capsule in comparison to the AcrySof (p > 0.99). Both, the Clareon (p = 0.01, 14.8 days) and the AcrySof IOL (p = 0.005, 15.7 days) showed a slower PCO development in comparison to the control (8.6 days). The fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were equally distributed between the two IOLs and differed from the control. CONCLUSIONS: A comparable performance has been found in the ex vivo formation of PCO between the two IOLs. Long-term clinical studies are necessary to reach final conclusions.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Posterior capsule opacification (PCO) after cataract surgery is influenced by intraocular lens (IOL) design and material. The following is an ex vivo comparison of PCO between the Clareon vs. the AcrySof IOL in human capsular bags. METHODS: Twenty cadaver capsular bags from 10 human donors were used, with the novel hydrophobic IOL (Clareon, CNA0T0) being implanted in one eye and the other eye of the same donor receiving the AcrySof IOL (SN60WF) following phacoemulsification cataract surgery. Five capsular bags of 3 donors served as controls without IOL. Cellular growth of lens epithelial cells was photo-documented daily. The primary endpoint was the time until full coverage of the posterior capsule by cells. Furthermore, immunofluorescence staining of capsular bags for the fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were performed. RESULTS: The new Clareon IOL did not show any disadvantages in terms of days until full cell coverage of the posterior capsule in comparison to the AcrySof (p > 0.99). Both, the Clareon (p = 0.01, 14.8 days) and the AcrySof IOL (p = 0.005, 15.7 days) showed a slower PCO development in comparison to the control (8.6 days). The fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were equally distributed between the two IOLs and differed from the control. CONCLUSIONS: A comparable performance has been found in the ex vivo formation of PCO between the two IOLs. Long-term clinical studies are necessary to reach final conclusions.

Key concepts: Medicine, Phacoemulsification, Posterior capsule opacification, Intraocular lens, Ophthalmology, Capsulorhexis, Capsule, Ex vivo

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of posterior capsule opacification of the Alcon Clareon IOL vs the Alcon Acrysof IOL using a human capsular bag model — Research Paper | ScholarLens