Fully-automated radiosynthesis of the amyloid tracer [11C] PiB via direct [11C]CO2 fixation-reduction
Pablo Buccino, Eduardo Savio, Williams Porcal
Abstract
Open-access reader
Pablo Buccino, Eduardo Savio, Williams Porcal
Abstract
Open-access reader
The β-amyloid radiotracer [ 11 C] PiB is extensively used for the Positron Emission Tomography (PET) diagnosis of Alzheimer’s Disease and related dementias. For clinical use, [ 11 C] PiB is produced using the 11 C-methylation method ([ 11 C] Methyl iodide or [ 11 C] methyl triflate as 11 C-methylation agents), which represents the most employed 11 C-labelling strategy for the synthesis of 11 C-radiopharmaceuticals. Recently, the use of direct [ 11 C]CO 2 fixation for the syntheses of 11 C-tracers has gained interest in the radiochemical community due to its importance in terms of radiochemical versatility and for permitting the direct employment of the cyclotron-produced precursor [ 11 C]CO 2 . This paper presents an optimised alternative one-pot methodology of [ 11 C]CO 2 fixation-reduction for the rapid synthesis of [ 11 C] PiB using an automated commercial platform and its quality control. [ 11 C] PiB was obtained from a (25.9 ± 13.2)% (Average ± Variation Coefficient, n = 3) (end of synthesis, decay corrected) radiochemical yield from trapped [ 11 C]CO 2 after 1 min of labelling time using PhSiH 3 / TBAF as the fixation-reduction system in Diglyme at 150 °C. The radiochemical purity was higher than 95% in all cases, and the molar activity was (61.4 ± 1.6) GBq/μmol. The radiochemical yield and activity (EOS) of formulated [ 11 C] PiB from cyclotron-produced [ 11 C]CO 2 was (14.8 ± 12.1)%, decay corrected) and 9.88 GBq (± 6.0%), respectively. These are higher values compared to that of the 11 C-methylation method with [ 11 C]CH 3 OTf (~ 8.3%). The viability of the system PhSiH 3 / TBAF to efficiently promote the radiosynthesis of [ 11 C] PiB via direct [ 11 C]CO 2 fixation-reduction has been demonstrated. [ 11 C] PiB was obtained through a fully automated radiosynthesis with a satisfactory yield, purity and molar activity. According to the results, the one-pot methodology employed could reliably yield sufficiently high tracer amounts for preclinical and clinical use.
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The β-amyloid radiotracer [ 11 C] PiB is extensively used for the Positron Emission Tomography (PET) diagnosis of Alzheimer’s Disease and related dementias. For clinical use, [ 11 C] PiB is produced using the 11 C-methylation method ([ 11 C] Methyl iodide or [ 11 C] methyl triflate as 11 C-methylation agents), which represents the most employed 11 C-labelling strategy for the synthesis of 11 C-radiopharmaceuticals. Recently, the use of direct [ 11 C]CO 2 fixation for the syntheses of 11 C-tracers has gained interest in the radiochemical community due to its importance in terms of radiochemical versatility and for permitting the direct employment of the cyclotron-produced precursor [ 11 C]CO 2 . This paper presents an optimised alternative one-pot methodology of [ 11 C]CO 2 fixation-reduction for the rapid synthesis of [ 11 C] PiB using an automated commercial platform and its quality control. [ 11 C] PiB was obtained from a (25.9 ± 13.2)% (Average ± Variation Coefficient, n = 3) (end of synthesis, decay corrected) radiochemical yield from trapped [ 11 C]CO 2 after 1 min of labelling time using PhSiH 3 / TBAF as the fixation-reduction system in Diglyme at 150 °C. The radiochemical purity was higher than 95% in all cases, and the molar activity was (61.4 ± 1.6) GBq/μmol. The radiochemical yield and activity (EOS) of formulated [ 11 C] PiB from cyclotron-produced [ 11 C]CO 2 was (14.8 ± 12.1)%, decay corrected) and 9.88 GBq (± 6.0%), respectively. These are higher values compared to that of the 11 C-methylation method with [ 11 C]CH 3 OTf (~ 8.3%). The viability of the system PhSiH 3 / TBAF to efficiently promote the radiosynthesis of [ 11 C] PiB via direct [ 11 C]CO 2 fixation-reduction has been demonstrated. [ 11 C] PiB was obtained through a fully automated radiosynthesis with a satisfactory yield, purity and molar activity. According to the results, the one-pot methodology employed could reliably yield sufficiently high tracer amounts for preclinical and clinical use.
Key concepts: Radiosynthesis, Chemistry, Radiochemistry, Methyl iodide, Yield (engineering), Positron emission tomography, Labelling, Nuclear chemistry