2019Gynecological EndocrinologyRequires access

Serum and peritoneal fluid levels of interleukin-6 and interleukin-37 as biomarkers for endometriosis

Jianfa Jiang, Zhaoying Jiang, Min Xue

Open publisher page 66 citations

Abstract

This study aimed to compare the levels of interleukin (IL)-1β, IL-6, IL-10, and IL-37 in the serum and peritoneal fluid of women with and without endometriosis. In addition, it aimed to determine the diagnostic values of the cytokines with significantly different concentrations. The levels of IL-1β, IL-6, IL-10, and IL-37 in the serum and peritoneal fluid samples of 40 women with endometriosis and 32 women without endometriosis were measured using an enzyme-linked immunosorbent assay. The serum and peritoneal fluid levels of IL-1β and IL-10 were not statistically significantly different between the endometriosis and control groups. The IL-6 and IL-37 levels in the serum and peritoneal fluid were higher in the endometriosis group than in the control group, and they were correlated with the stage of endometriosis. The AUC for the IL-37 was 0.897 for the serum and 0.934 for the peritoneal fluid, while the AUC for the IL-6 was 0.905 for the serum and 0.952 for the peritoneal fluid. Our results suggest that the serum and peritoneal fluid IL-6 and IL-37 levels were significantly increased in the endometriosis patients, indicating that these cytokines may serve as biomarkers for the diagnosis of endometriosis.

About this research paper

What this paper is about

This study aimed to compare the levels of interleukin (IL)-1β, IL-6, IL-10, and IL-37 in the serum and peritoneal fluid of women with and without endometriosis. In addition, it aimed to determine the diagnostic values of the cytokines with significantly different concentrations. The levels of IL-1β, IL-6, IL-10, and IL-37 in the serum and peritoneal fluid samples of 40 women with endometriosis and 32 women without endometriosis were measured using an enzyme-linked immunosorbent assay. The serum and peritoneal fluid levels of IL-1β and IL-10 were not statistically significantly different between the endometriosis and control groups. The IL-6 and IL-37 levels in the serum and peritoneal fluid were higher in the endometriosis group than in the control group, and they were correlated with the stage of endometriosis. The AUC for the IL-37 was 0.897 for the serum and 0.934 for the peritoneal fluid, while the AUC for the IL-6 was 0.905 for the serum and 0.952 for the peritoneal fluid. Our results suggest that the serum and peritoneal fluid IL-6 and IL-37 levels were significantly increased in the endometriosis patients, indicating that these cytokines may serve as biomarkers for the diagnosis of endometriosis.

Why it matters

OpenAlex reports 66 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study aimed to compare the levels of interleukin (IL)-1β, IL-6, IL-10, and IL-37 in the serum and peritoneal fluid of women with and without endometriosis. In addition, it aimed to determine the diagnostic values of the cytokines with significantly different concentrations. The levels of IL-1β, IL-6, IL-10, and IL-37 in the serum and peritoneal fluid samples of 40 women with endometriosis and 32 women without endometriosis were measured using an enzyme-linked immunosorbent assay. The serum and peritoneal fluid levels of IL-1β and IL-10 were not statistically significantly different between the endometriosis and control groups. The IL-6 and IL-37 levels in the serum and peritoneal fluid were higher in the endometriosis group than in the control group, and they were correlated with the stage of endometriosis. The AUC for the IL-37 was 0.897 for the serum and 0.934 for the peritoneal fluid, while the AUC for the IL-6 was 0.905 for the serum and 0.952 for the peritoneal fluid. Our results suggest that the serum and peritoneal fluid IL-6 and IL-37 levels were significantly increased in the endometriosis patients, indicating that these cytokines may serve as biomarkers for the diagnosis of endometriosis.

Key concepts: Peritoneal fluid, Endometriosis, Medicine, Internal medicine, Interleukin, Interleukin 6, Cytokine, Endocrinology

Related papers

Back to paper searchBrowse research topicsOriginal source
Serum and peritoneal fluid levels of interleukin-6 and interleukin-37 as biomarkers for endometriosis — Research Paper | ScholarLens