2018Nuclear Technology and Radiation ProtectionOpen access

The impact of field size and radiation quality on KAP-meter and CT-chamber response

Miloš Živanović, Nikola Kržanović, Djordje Lazarević, A. Boziari, Panagiota Konstantinou

Open full text 1 citations

Abstract

Kerma-area product and kerma-length product are important practical dosimetric quantities used in diagnostic radiology. These quantities are measured by special types of dosimeters which are calibrated in standard radiation qualities established in calibration laboratories. However, in clinical practice the dosimeters are used in different conditions, including the radiation quality and field size. In this paper, energy and field size dependence are studied for both types of dosimeters. One dosimeter of each type is tested. The KAP-meter has shown significant dependence on both radiation quality and field size, while the dependence of the CT-chamber is much less pronounced. Two different approaches can be used to correct for the difference between conditions during calibration and in clinical practice. When the clinical beam is well characterized and energy and field size dependence of the dosimeter are well known, the optimum solution is to apply the adequate correction factor to the measurements, keeping measurement uncertainty as low as possible. If this is not the case, the above limitations must be taken under consideration in the calculation of the expanded uncertainty budget.

Open-access reader

About this research paper

What this paper is about

Kerma-area product and kerma-length product are important practical dosimetric quantities used in diagnostic radiology. These quantities are measured by special types of dosimeters which are calibrated in standard radiation qualities established in calibration laboratories. However, in clinical practice the dosimeters are used in different conditions, including the radiation quality and field size. In this paper, energy and field size dependence are studied for both types of dosimeters. One dosimeter of each type is tested. The KAP-meter has shown significant dependence on both radiation quality and field size, while the dependence of the CT-chamber is much less pronounced. Two different approaches can be used to correct for the difference between conditions during calibration and in clinical practice. When the clinical beam is well characterized and energy and field size dependence of the dosimeter are well known, the optimum solution is to apply the adequate correction factor to the measurements, keeping measurement uncertainty as low as possible. If this is not the case, the above limitations must be taken under consideration in the calculation of the expanded uncertainty budget.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Kerma-area product and kerma-length product are important practical dosimetric quantities used in diagnostic radiology. These quantities are measured by special types of dosimeters which are calibrated in standard radiation qualities established in calibration laboratories. However, in clinical practice the dosimeters are used in different conditions, including the radiation quality and field size. In this paper, energy and field size dependence are studied for both types of dosimeters. One dosimeter of each type is tested. The KAP-meter has shown significant dependence on both radiation quality and field size, while the dependence of the CT-chamber is much less pronounced. Two different approaches can be used to correct for the difference between conditions during calibration and in clinical practice. When the clinical beam is well characterized and energy and field size dependence of the dosimeter are well known, the optimum solution is to apply the adequate correction factor to the measurements, keeping measurement uncertainty as low as possible. If this is not the case, the above limitations must be taken under consideration in the calculation of the expanded uncertainty budget.

Key concepts: Dosimeter, Kerma, Calibration, Metre, Radiation, Materials science, Nuclear engineering, Field size