Goldmann applanation tonometer versus ocular response analyzer for measuring intraocular pressure after congenital cataract surgery

Sepehr Feizi, Amir Faramarzi, Bahareh Kheiri

Open publisher page 1 citations

Abstract

PURPOSE: To compare intraocular pressure measured using the Goldmann applanation tonometer with that measured using the ocular response analyzer after congenital cataract surgery. METHODS: This study included 113 eyes of 64 patients who underwent lensectomy and vitrectomy. In all, 36 eyes remained aphakic after surgery. Intraocular lens implantation was performed at the time of surgery in 47 eyes and secondarily in 30 eyes. Corneal hysteresis, corneal resistance factor, and cornea-compensated intraocular pressure were measured. The influences of independent factors on the difference between the cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer were investigated using linear regression analyses. Agreement between the two tonometers was investigated using the Bland and Altman and 95% limits of agreement analysis. RESULTS: Central corneal thickness, corneal hysteresis, and corneal resistance factor were 591.2 ± 53.3 µm, 10.83 ± 2.27 mmHg, and 11.36 ± 2.14 mmHg, respectively. Cornea-compensated intraocular pressure (16.75 ± 4.82 mmHg) was significantly higher than intraocular pressure measured with Goldmann applanation tonometer (14.41 ± 2.27 mmHg, p < 0.001). Central corneal thickness (p = 0.02) and corneal hysteresis (p < 0.001) were identified as the main predictors of difference between cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer readings. A 95% limits of agreement for cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer was between -4.86 and 9.53 mmHg in the entire group. Cornea-compensated intraocular pressure showed the best agreement with intraocular pressure measured with Goldmann applanation tonometer in the primary pseudophakic subgroup as compared to the other subgroups. CONCLUSION: The Goldmann applanation tonometer and ocular response analyzer cannot be used interchangeably for measuring intraocular pressure after congenital cataract surgery. The difference between the cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer was primarily affected by central corneal thickness and corneal hysteresis. Among the subgroups, the primary pseudophakic subgroup had the thinnest cornea and the highest corneal hysteresis values and demonstrated the best agreement between the two tonometers.

About this research paper

What this paper is about

PURPOSE: To compare intraocular pressure measured using the Goldmann applanation tonometer with that measured using the ocular response analyzer after congenital cataract surgery. METHODS: This study included 113 eyes of 64 patients who underwent lensectomy and vitrectomy. In all, 36 eyes remained aphakic after surgery. Intraocular lens implantation was performed at the time of surgery in 47 eyes and secondarily in 30 eyes. Corneal hysteresis, corneal resistance factor, and cornea-compensated intraocular pressure were measured. The influences of independent factors on the difference between the cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer were investigated using linear regression analyses. Agreement between the two tonometers was investigated using the Bland and Altman and 95% limits of agreement analysis. RESULTS: Central corneal thickness, corneal hysteresis, and corneal resistance factor were 591.2 ± 53.3 µm, 10.83 ± 2.27 mmHg, and 11.36 ± 2.14 mmHg, respectively. Cornea-compensated intraocular pressure (16.75 ± 4.82 mmHg) was significantly higher than intraocular pressure measured with Goldmann applanation tonometer (14.41 ± 2.27 mmHg, p < 0.001). Central corneal thickness (p = 0.02) and corneal hysteresis (p < 0.001) were identified as the main predictors of difference between cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer readings. A 95% limits of agreement for cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer was between -4.86 and 9.53 mmHg in the entire group. Cornea-compensated intraocular pressure showed the best agreement with intraocular pressure measured with Goldmann applanation tonometer in the primary pseudophakic subgroup as compared to the other subgroups. CONCLUSION: The Goldmann applanation tonometer and ocular response analyzer cannot be used interchangeably for measuring intraocular pressure after congenital cataract surgery. The difference between the cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer was primarily affected by central corneal thickness and corneal hysteresis. Among the subgroups, the primary pseudophakic subgroup had the thinnest cornea and the highest corneal hysteresis values and demonstrated the best agreement between the two tonometers.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To compare intraocular pressure measured using the Goldmann applanation tonometer with that measured using the ocular response analyzer after congenital cataract surgery. METHODS: This study included 113 eyes of 64 patients who underwent lensectomy and vitrectomy. In all, 36 eyes remained aphakic after surgery. Intraocular lens implantation was performed at the time of surgery in 47 eyes and secondarily in 30 eyes. Corneal hysteresis, corneal resistance factor, and cornea-compensated intraocular pressure were measured. The influences of independent factors on the difference between the cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer were investigated using linear regression analyses. Agreement between the two tonometers was investigated using the Bland and Altman and 95% limits of agreement analysis. RESULTS: Central corneal thickness, corneal hysteresis, and corneal resistance factor were 591.2 ± 53.3 µm, 10.83 ± 2.27 mmHg, and 11.36 ± 2.14 mmHg, respectively. Cornea-compensated intraocular pressure (16.75 ± 4.82 mmHg) was significantly higher than intraocular pressure measured with Goldmann applanation tonometer (14.41 ± 2.27 mmHg, p < 0.001). Central corneal thickness (p = 0.02) and corneal hysteresis (p < 0.001) were identified as the main predictors of difference between cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer readings. A 95% limits of agreement for cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer was between -4.86 and 9.53 mmHg in the entire group. Cornea-compensated intraocular pressure showed the best agreement with intraocular pressure measured with Goldmann applanation tonometer in the primary pseudophakic subgroup as compared to the other subgroups. CONCLUSION: The Goldmann applanation tonometer and ocular response analyzer cannot be used interchangeably for measuring intraocular pressure after congenital cataract surgery. The difference between the cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer was primarily affected by central corneal thickness and corneal hysteresis. Among the subgroups, the primary pseudophakic subgroup had the thinnest cornea and the highest corneal hysteresis values and demonstrated the best agreement between the two tonometers.

Key concepts: Intraocular pressure, Medicine, Ophthalmology, Cataract surgery, Applanation tonometry, Goldmann Applanation Tonometer, Optometry, Blood pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
Goldmann applanation tonometer versus ocular response analyzer for measuring intraocular pressure after congenital cataract surgery — Research Paper | ScholarLens