2013PubMedRequires access

[Identification and genotyping of difficult blood groups in the patients with phymatosis].

Chao Wang, Suping Li, Min Li, Xue-Zhong Wu, Xin Xing, Rong Lyu

Open publisher page 1 citations

Abstract

In part of the patients with blood disease or malignant tumors, especially those with leukemia and multiple myeloma, the disease state and unsuitable treatment often resulted in the inconsistence between positive and negative ABO blood group, displaying attenuation of the antigen or antibody of ABO blood group. This study was purposed to analyze the course of inconsistence between positive and negative ABO blood group and to perform the correct typing of erythrocytes and genes. The serology, absorption and elution test were used to examine the 12 tumor patient of the inconsistence between positive and negative typing. The 6th, 7th exon and 5-7th introns were amplified by PCR for questionable samples, and the gene sequencing of exon was performed. The results showed that 9 specimens were determined as 6 of A group, 2 of O group, 1 of B group, 3 cases were identified as O46, B108, and A102 group, respectively, by the serology, absorption and elution typing. The genotype of 2 cases among them was not identified because of the erroneous PCR amplified result or the contradicted sequencing results, failing to determine the ABO genotype. It is concluded that the serological method for blood grouping, genotyping, absorption and elution method can be used for the blood samples unable to typing because of the inconsistence between positive and negative typing of ABO group, therefore, guaranteeing the safety and effectiveness.

About this research paper

What this paper is about

In part of the patients with blood disease or malignant tumors, especially those with leukemia and multiple myeloma, the disease state and unsuitable treatment often resulted in the inconsistence between positive and negative ABO blood group, displaying attenuation of the antigen or antibody of ABO blood group. This study was purposed to analyze the course of inconsistence between positive and negative ABO blood group and to perform the correct typing of erythrocytes and genes. The serology, absorption and elution test were used to examine the 12 tumor patient of the inconsistence between positive and negative typing. The 6th, 7th exon and 5-7th introns were amplified by PCR for questionable samples, and the gene sequencing of exon was performed. The results showed that 9 specimens were determined as 6 of A group, 2 of O group, 1 of B group, 3 cases were identified as O46, B108, and A102 group, respectively, by the serology, absorption and elution typing. The genotype of 2 cases among them was not identified because of the erroneous PCR amplified result or the contradicted sequencing results, failing to determine the ABO genotype. It is concluded that the serological method for blood grouping, genotyping, absorption and elution method can be used for the blood samples unable to typing because of the inconsistence between positive and negative typing of ABO group, therefore, guaranteeing the safety and effectiveness.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In part of the patients with blood disease or malignant tumors, especially those with leukemia and multiple myeloma, the disease state and unsuitable treatment often resulted in the inconsistence between positive and negative ABO blood group, displaying attenuation of the antigen or antibody of ABO blood group. This study was purposed to analyze the course of inconsistence between positive and negative ABO blood group and to perform the correct typing of erythrocytes and genes. The serology, absorption and elution test were used to examine the 12 tumor patient of the inconsistence between positive and negative typing. The 6th, 7th exon and 5-7th introns were amplified by PCR for questionable samples, and the gene sequencing of exon was performed. The results showed that 9 specimens were determined as 6 of A group, 2 of O group, 1 of B group, 3 cases were identified as O46, B108, and A102 group, respectively, by the serology, absorption and elution typing. The genotype of 2 cases among them was not identified because of the erroneous PCR amplified result or the contradicted sequencing results, failing to determine the ABO genotype. It is concluded that the serological method for blood grouping, genotyping, absorption and elution method can be used for the blood samples unable to typing because of the inconsistence between positive and negative typing of ABO group, therefore, guaranteeing the safety and effectiveness.

Key concepts: ABO blood group system, Genotyping, Typing, Serology, Genotype, Biology, Medicine, Immunology

Related papers

Back to paper searchBrowse research topicsOriginal source
[Identification and genotyping of difficult blood groups in the patients with phymatosis]. — Research Paper | ScholarLens