1981OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)Requires access

Demonstration of Wellman-Lord/allied chemical FGD technology: demonstration test second year results. Final report February 73-October 79

Robert Adams, Steven Mulligan, R.R. Swanson

Open publisher page 0 citations

Abstract

The report gives results of an evaluation of the performance (over a 2-year period) of a full-scale flue gas desulfurization (FGD) unit to demonstrate the Wellman-Lord/Allied Chemical process. The process is regenerable, employing sodium sulfite wet scrubbing, thermal regeneration of the spent scrubber solution, and reduction to elemental sulfur of the recovered SO/sub 2/. Tests indicate that 89-90% of the SO/sub 2/ can be removed readily from the flue gas in a long-term dependable manner. However, best performance of the regeneration system for 1 year was limited to only 61% of the time called upon to operate. Major operating limitations were reduction unit problems, but unscheduled evaporator and booster blower outages, as well as start-ups and shutdowns, also contributed to downtime. As expected, process energy requirements, primarily for thermal regeneration of the scrubber solution and subsequent recovery of SO2, were quite large, amounting to 12% of the boiler heat input derived from fuel. Actual annualized operating cost was 14.9 mills/kWh, at 1978 prices for raw materials and utilities. Credits for the sale of byproduct sulfur were only 0.2 mills/kWh. The reported operation and performance occurred after some modification to the boiler to increase inlet flue gas temperature and after implementingmore » FGD plant improvements identified during initial operation.« less

About this research paper

What this paper is about

The report gives results of an evaluation of the performance (over a 2-year period) of a full-scale flue gas desulfurization (FGD) unit to demonstrate the Wellman-Lord/Allied Chemical process. The process is regenerable, employing sodium sulfite wet scrubbing, thermal regeneration of the spent scrubber solution, and reduction to elemental sulfur of the recovered SO/sub 2/. Tests indicate that 89-90% of the SO/sub 2/ can be removed readily from the flue gas in a long-term dependable manner. However, best performance of the regeneration system for 1 year was limited to only 61% of the time called upon to operate. Major operating limitations were reduction unit problems, but unscheduled evaporator and booster blower outages, as well as start-ups and shutdowns, also contributed to downtime. As expected, process energy requirements, primarily for thermal regeneration of the scrubber solution and subsequent recovery of SO2, were quite large, amounting to 12% of the boiler heat input derived from fuel. Actual annualized operating cost was 14.9 mills/kWh, at 1978 prices for raw materials and utilities. Credits for the sale of byproduct sulfur were only 0.2 mills/kWh. The reported operation and performance occurred after some modification to the boiler to increase inlet flue gas temperature and after implementingmore » FGD plant improvements identified during initial operation.« less

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The report gives results of an evaluation of the performance (over a 2-year period) of a full-scale flue gas desulfurization (FGD) unit to demonstrate the Wellman-Lord/Allied Chemical process. The process is regenerable, employing sodium sulfite wet scrubbing, thermal regeneration of the spent scrubber solution, and reduction to elemental sulfur of the recovered SO/sub 2/. Tests indicate that 89-90% of the SO/sub 2/ can be removed readily from the flue gas in a long-term dependable manner. However, best performance of the regeneration system for 1 year was limited to only 61% of the time called upon to operate. Major operating limitations were reduction unit problems, but unscheduled evaporator and booster blower outages, as well as start-ups and shutdowns, also contributed to downtime. As expected, process energy requirements, primarily for thermal regeneration of the scrubber solution and subsequent recovery of SO2, were quite large, amounting to 12% of the boiler heat input derived from fuel. Actual annualized operating cost was 14.9 mills/kWh, at 1978 prices for raw materials and utilities. Credits for the sale of byproduct sulfur were only 0.2 mills/kWh. The reported operation and performance occurred after some modification to the boiler to increase inlet flue gas temperature and after implementingmore » FGD plant improvements identified during initial operation.« less

Key concepts: Scrubber, Waste management, Flue-gas desulfurization, Flue gas, Boiler (water heating), Engineering, Environmental science, Raw material

Related papers

Back to paper searchBrowse research topicsOriginal source
Demonstration of Wellman-Lord/allied chemical FGD technology: demonstration test second year results. Final report February 73-October 79 — Research Paper | ScholarLens