2016Global Journal of Health ScienceOpen access

Intraocular Foreign Body Removal by 23-Gauge Micro Incision Vitrectomy Surgery and Back Flush Flute Needle: A Case Series Study

Mohamadhosein Ahoor, Rana Sorkhabi

Open full text 0 citations

Abstract

BACKGROUND: This study aimed to consider a new technique to extract an intraocular foreign body by 23-gauge micro incision vitrectomy surgery (23G-MIVS). METHOD: This case series was done on Patients with intraocular foreign bodies and cataract during 2012-2015 in Tabriz University of Medical Sciences. Phacoemulsification and aspiration of lens nucleus, intraocular lens implantation, 23G-MIVS, and extraction of the foreign body were performed on patients. The foreign body was removed through a posterior capsulor hexis, anterior continuous curvilinear capsulorhexis, and a corneal incision. In all cases, the foreign body was safely removed through the corneal incision with back flush Flute Needle, and IOL was implanted and well positioned. The surgical incision did not require suturing. RESULTS: This technique was successful for the patients and the corneal endothelial cell density was maintained over 2000 cells/mm2 in all cases during recent follow-up examinations. CONCLUSION: We found that 23G-MIVS with this technique is suitable to remove the foreign body. It is safe, without complications, and can be used without enlarging the 23-gauge sclerotomy.

About this research paper

What this paper is about

BACKGROUND: This study aimed to consider a new technique to extract an intraocular foreign body by 23-gauge micro incision vitrectomy surgery (23G-MIVS). METHOD: This case series was done on Patients with intraocular foreign bodies and cataract during 2012-2015 in Tabriz University of Medical Sciences. Phacoemulsification and aspiration of lens nucleus, intraocular lens implantation, 23G-MIVS, and extraction of the foreign body were performed on patients. The foreign body was removed through a posterior capsulor hexis, anterior continuous curvilinear capsulorhexis, and a corneal incision. In all cases, the foreign body was safely removed through the corneal incision with back flush Flute Needle, and IOL was implanted and well positioned. The surgical incision did not require suturing. RESULTS: This technique was successful for the patients and the corneal endothelial cell density was maintained over 2000 cells/mm2 in all cases during recent follow-up examinations. CONCLUSION: We found that 23G-MIVS with this technique is suitable to remove the foreign body. It is safe, without complications, and can be used without enlarging the 23-gauge sclerotomy.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: This study aimed to consider a new technique to extract an intraocular foreign body by 23-gauge micro incision vitrectomy surgery (23G-MIVS). METHOD: This case series was done on Patients with intraocular foreign bodies and cataract during 2012-2015 in Tabriz University of Medical Sciences. Phacoemulsification and aspiration of lens nucleus, intraocular lens implantation, 23G-MIVS, and extraction of the foreign body were performed on patients. The foreign body was removed through a posterior capsulor hexis, anterior continuous curvilinear capsulorhexis, and a corneal incision. In all cases, the foreign body was safely removed through the corneal incision with back flush Flute Needle, and IOL was implanted and well positioned. The surgical incision did not require suturing. RESULTS: This technique was successful for the patients and the corneal endothelial cell density was maintained over 2000 cells/mm2 in all cases during recent follow-up examinations. CONCLUSION: We found that 23G-MIVS with this technique is suitable to remove the foreign body. It is safe, without complications, and can be used without enlarging the 23-gauge sclerotomy.

Key concepts: Medicine, Capsulorhexis, Vitrectomy, Phacoemulsification, Foreign body, Ophthalmology, Surgery, Intraocular lens

Related papers

Back to paper searchBrowse research topicsOriginal source
Intraocular Foreign Body Removal by 23-Gauge Micro Incision Vitrectomy Surgery and Back Flush Flute Needle: A Case Series Study — Research Paper | ScholarLens