2016Review of Scientific InstrumentsRequires access

Design and analysis of a novel virtual gyroscope with multi-gyroscope and accelerometer array

Luo Zhang, Chaojun Liu, Shuai Yu, Shengzhi Zhang, Sheng Liu

Open publisher page 22 citations

Abstract

A new virtual gyroscope with multi-gyroscope and accelerometer array (MGAA) is proposed in this article for improving the performance of angular rate measurement. Outputs of the virtual gyroscope are obtained by merging the signals from gyroscopes and accelerometers through a novel Kalman filter, which intentionally takes the consideration of the MEMS gyroscope error model and kinematics theory of rigid body. A typical configuration of the virtual gyroscope, consisting of four accelerometers and three gyroscopes mounted on designated positions, is initiated to verify the feasibility of the virtual gyroscope with MGAA. Static test and dynamic test are performed subsequently to evaluate its performance. The angular random walk (ARW) and bias instability, two static performance parameters of gyroscope, are reduced from 0.019°/√s and 14.4°/h to 0.0074°/√s and 8.7°/h, respectively. The average root mean square error (RMSE) is reduced from 0.274°/s to 0.133°/s under dynamic test. Compared with the published multi-gyroscope array method, the virtual gyroscope proposed here has a better performance both in static and dynamic tests, with improvement factors of ARW and RMSE about 44.1% and 44.5% higher, respectively.

About this research paper

What this paper is about

A new virtual gyroscope with multi-gyroscope and accelerometer array (MGAA) is proposed in this article for improving the performance of angular rate measurement. Outputs of the virtual gyroscope are obtained by merging the signals from gyroscopes and accelerometers through a novel Kalman filter, which intentionally takes the consideration of the MEMS gyroscope error model and kinematics theory of rigid body. A typical configuration of the virtual gyroscope, consisting of four accelerometers and three gyroscopes mounted on designated positions, is initiated to verify the feasibility of the virtual gyroscope with MGAA. Static test and dynamic test are performed subsequently to evaluate its performance. The angular random walk (ARW) and bias instability, two static performance parameters of gyroscope, are reduced from 0.019°/√s and 14.4°/h to 0.0074°/√s and 8.7°/h, respectively. The average root mean square error (RMSE) is reduced from 0.274°/s to 0.133°/s under dynamic test. Compared with the published multi-gyroscope array method, the virtual gyroscope proposed here has a better performance both in static and dynamic tests, with improvement factors of ARW and RMSE about 44.1% and 44.5% higher, respectively.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new virtual gyroscope with multi-gyroscope and accelerometer array (MGAA) is proposed in this article for improving the performance of angular rate measurement. Outputs of the virtual gyroscope are obtained by merging the signals from gyroscopes and accelerometers through a novel Kalman filter, which intentionally takes the consideration of the MEMS gyroscope error model and kinematics theory of rigid body. A typical configuration of the virtual gyroscope, consisting of four accelerometers and three gyroscopes mounted on designated positions, is initiated to verify the feasibility of the virtual gyroscope with MGAA. Static test and dynamic test are performed subsequently to evaluate its performance. The angular random walk (ARW) and bias instability, two static performance parameters of gyroscope, are reduced from 0.019°/√s and 14.4°/h to 0.0074°/√s and 8.7°/h, respectively. The average root mean square error (RMSE) is reduced from 0.274°/s to 0.133°/s under dynamic test. Compared with the published multi-gyroscope array method, the virtual gyroscope proposed here has a better performance both in static and dynamic tests, with improvement factors of ARW and RMSE about 44.1% and 44.5% higher, respectively.

Key concepts: Gyroscope, Accelerometer, Rate integrating gyroscope, Vibrating structure gyroscope, Kalman filter, Inertial measurement unit, Computer science, Kinematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Design and analysis of a novel virtual gyroscope with multi-gyroscope and accelerometer array — Research Paper | ScholarLens