2009PubMedRequires access

[Comparison of ICP-MS and two other analytical methods for determination of selenium content in Cordyceps militaris].

Ying Wang, Mei Tie, Pingli Kang, Yong-Tong Lü, Songbin Ben, Chang-Lan Chen

Open publisher page 1 citations

Abstract

Samples were digested by microwave digestion. The selenium content in selenium enriched Cordyceps militaris was determined by ICP-MS method, HPLC/fluorometric method, and 3,3-diaminobenzidine method separately. And the detection conditions, the lowest detection limit and the relative standard deviation (RSD) of the three determination methods were compared. The detection conditions of the three methods for the detection of selenium content in selenium enriched Cordyceps militaris were established. It was showed that the lowest detection limit of ICP-MS method, HPLC/fluorometric method, and 3,3-diaminobenzidine method was 0.260 7, 0.182 1 and 10.485 9 microg x L(-1) respectively, and this means that the lowest detection limit of ICP-MS method was the lowest and that of 3,3-diaminobenzidine method was the highest. For the same sample the relative standard deviation (RSD) of ICP-MS method was the lowest and the RSD of 3,3-diaminobenzidine method was the highest. It was recommended that selenium content is determined by ICP-MS and HPLC/fluorometric method when the selenium in the sample is very low and by 3,3-diaminobenzidine method when the content is rather high.

About this research paper

What this paper is about

Samples were digested by microwave digestion. The selenium content in selenium enriched Cordyceps militaris was determined by ICP-MS method, HPLC/fluorometric method, and 3,3-diaminobenzidine method separately. And the detection conditions, the lowest detection limit and the relative standard deviation (RSD) of the three determination methods were compared. The detection conditions of the three methods for the detection of selenium content in selenium enriched Cordyceps militaris were established. It was showed that the lowest detection limit of ICP-MS method, HPLC/fluorometric method, and 3,3-diaminobenzidine method was 0.260 7, 0.182 1 and 10.485 9 microg x L(-1) respectively, and this means that the lowest detection limit of ICP-MS method was the lowest and that of 3,3-diaminobenzidine method was the highest. For the same sample the relative standard deviation (RSD) of ICP-MS method was the lowest and the RSD of 3,3-diaminobenzidine method was the highest. It was recommended that selenium content is determined by ICP-MS and HPLC/fluorometric method when the selenium in the sample is very low and by 3,3-diaminobenzidine method when the content is rather high.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Samples were digested by microwave digestion. The selenium content in selenium enriched Cordyceps militaris was determined by ICP-MS method, HPLC/fluorometric method, and 3,3-diaminobenzidine method separately. And the detection conditions, the lowest detection limit and the relative standard deviation (RSD) of the three determination methods were compared. The detection conditions of the three methods for the detection of selenium content in selenium enriched Cordyceps militaris were established. It was showed that the lowest detection limit of ICP-MS method, HPLC/fluorometric method, and 3,3-diaminobenzidine method was 0.260 7, 0.182 1 and 10.485 9 microg x L(-1) respectively, and this means that the lowest detection limit of ICP-MS method was the lowest and that of 3,3-diaminobenzidine method was the highest. For the same sample the relative standard deviation (RSD) of ICP-MS method was the lowest and the RSD of 3,3-diaminobenzidine method was the highest. It was recommended that selenium content is determined by ICP-MS and HPLC/fluorometric method when the selenium in the sample is very low and by 3,3-diaminobenzidine method when the content is rather high.

Key concepts: Selenium, Detection limit, Chemistry, Chromatography, Cordyceps militaris, Relative standard deviation, High-performance liquid chromatography, Microwave digestion

Related papers

Back to paper searchBrowse research topicsOriginal source
[Comparison of ICP-MS and two other analytical methods for determination of selenium content in Cordyceps militaris]. — Research Paper | ScholarLens