2005•PubMedRequires access

[Determination of uric acid by chemiluminescence].

Erbao Liu, Hong-qing Wei

Open publisher page 7 citations

Abstract

A novel chemiluminescence method for the determination of uric acid based on its inhibitory effect on the catalysis of Co2+ for the oxidation of luminol by H2O2 is described. The proposed method is simple, very sensitive and inexpensive. The decrease of cheniluminescence intensity is linearly correlated with uric acid concentration. The calibration graph is linear over the range of 1.0 x 10(-10) - 7.0 x 10(-6) mol x L(-1) and the detection limit is 1.1 x 10(-11) mol x L(-1). The relative standard deviation (RSD) for 5.0 x 10(-8) is 1.9% (n=4). The method has been successfully applied to the determination of uric acid in human urine and serum samples.

About this research paper

What this paper is about

A novel chemiluminescence method for the determination of uric acid based on its inhibitory effect on the catalysis of Co2+ for the oxidation of luminol by H2O2 is described. The proposed method is simple, very sensitive and inexpensive. The decrease of cheniluminescence intensity is linearly correlated with uric acid concentration. The calibration graph is linear over the range of 1.0 x 10(-10) - 7.0 x 10(-6) mol x L(-1) and the detection limit is 1.1 x 10(-11) mol x L(-1). The relative standard deviation (RSD) for 5.0 x 10(-8) is 1.9% (n=4). The method has been successfully applied to the determination of uric acid in human urine and serum samples.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel chemiluminescence method for the determination of uric acid based on its inhibitory effect on the catalysis of Co2+ for the oxidation of luminol by H2O2 is described. The proposed method is simple, very sensitive and inexpensive. The decrease of cheniluminescence intensity is linearly correlated with uric acid concentration. The calibration graph is linear over the range of 1.0 x 10(-10) - 7.0 x 10(-6) mol x L(-1) and the detection limit is 1.1 x 10(-11) mol x L(-1). The relative standard deviation (RSD) for 5.0 x 10(-8) is 1.9% (n=4). The method has been successfully applied to the determination of uric acid in human urine and serum samples.

Key concepts: Chemiluminescence, Uric acid, Detection limit, Calibration curve, Luminol, Chemistry, Relative standard deviation, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of uric acid by chemiluminescence]. — Research Paper | ScholarLens