2004•Physical Testing and Chemical AnalysisRequires access

REVERSE-FI INHIBITION-CHEMILUMINESCENCE DETERMINATION OF URIC ACID

Peng Qu, Zhujun Zhang

Open publisher page 0 citations

Abstract

The optimum conditions of the new chemiluminescence (CL) reaction system of oxidation of luminol by P-Mo-V-heteropoly acid in sodium hydroxide medium, and the inhibition of the CL emitted by the presence of uric acid were studied. It was found that the relative CL-intensity held a linear relationship with the concentration of uric acid in the range from 1.0×10~(-7) to 1.0×10~(-4)g per ml of solution, with a detection limit of (4×10~(-8)g·ml~(-1)). Test for its precision was made at the concentration level of 5.0×10~(-6)g·ml~(-1) for 11 successive determinations and the RSD obtained was 1.2%. A flow-injection installation with reverse flow device was described. The apparatus has been satisfactorily used in the determination of uric acid in urine samples.

About this research paper

What this paper is about

The optimum conditions of the new chemiluminescence (CL) reaction system of oxidation of luminol by P-Mo-V-heteropoly acid in sodium hydroxide medium, and the inhibition of the CL emitted by the presence of uric acid were studied. It was found that the relative CL-intensity held a linear relationship with the concentration of uric acid in the range from 1.0×10~(-7) to 1.0×10~(-4)g per ml of solution, with a detection limit of (4×10~(-8)g·ml~(-1)). Test for its precision was made at the concentration level of 5.0×10~(-6)g·ml~(-1) for 11 successive determinations and the RSD obtained was 1.2%. A flow-injection installation with reverse flow device was described. The apparatus has been satisfactorily used in the determination of uric acid in urine samples.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The optimum conditions of the new chemiluminescence (CL) reaction system of oxidation of luminol by P-Mo-V-heteropoly acid in sodium hydroxide medium, and the inhibition of the CL emitted by the presence of uric acid were studied. It was found that the relative CL-intensity held a linear relationship with the concentration of uric acid in the range from 1.0×10~(-7) to 1.0×10~(-4)g per ml of solution, with a detection limit of (4×10~(-8)g·ml~(-1)). Test for its precision was made at the concentration level of 5.0×10~(-6)g·ml~(-1) for 11 successive determinations and the RSD obtained was 1.2%. A flow-injection installation with reverse flow device was described. The apparatus has been satisfactorily used in the determination of uric acid in urine samples.

Key concepts: Chemiluminescence, Uric acid, Chemistry, Sodium hydroxide, Detection limit, Luminol, Chromatography, Hydroxide

Related papers

Back to paper searchBrowse research topicsOriginal source
REVERSE-FI INHIBITION-CHEMILUMINESCENCE DETERMINATION OF URIC ACID — Research Paper | ScholarLens