2009•Chongqing Yike Daxue xuebaoRequires access

Flow injection chemiluminescence determination of uric acid with micropipe-chip

Gang Yi

Open publisher page 0 citations

Abstract

Objective:To establish a flow injection chemiluminescence determination method with micropipe-chip for speedy determination of uric acid in clinical samples.Methods:Basing on the rule that uric acid can greatly enhance the chemiluminescence emission intensity of K4Fe(CN)6-K3Fe(CN)6-luminol system,the prepared micropipe-chip was used to analyze the uric acid in serum under the selective conditions.Results:The enhancing chemiluminescence intensity was proportional to uric acid concentration over a range 2.0×10-5~1.0×10-2 g/L.The detection limit(3σ) was 4.6×10-7 g/L.The relative standard deviation(RSD) was 3.09% and the recovery test results were 94.0%,99.7%,and 107.8%.Conclusion:The manufacture technique of micropipr-chip is simple but the proposed determination method of uric acid in human serum is sensitive,fast and convenient.

About this research paper

What this paper is about

Objective:To establish a flow injection chemiluminescence determination method with micropipe-chip for speedy determination of uric acid in clinical samples.Methods:Basing on the rule that uric acid can greatly enhance the chemiluminescence emission intensity of K4Fe(CN)6-K3Fe(CN)6-luminol system,the prepared micropipe-chip was used to analyze the uric acid in serum under the selective conditions.Results:The enhancing chemiluminescence intensity was proportional to uric acid concentration over a range 2.0×10-5~1.0×10-2 g/L.The detection limit(3σ) was 4.6×10-7 g/L.The relative standard deviation(RSD) was 3.09% and the recovery test results were 94.0%,99.7%,and 107.8%.Conclusion:The manufacture technique of micropipr-chip is simple but the proposed determination method of uric acid in human serum is sensitive,fast and convenient.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a flow injection chemiluminescence determination method with micropipe-chip for speedy determination of uric acid in clinical samples.Methods:Basing on the rule that uric acid can greatly enhance the chemiluminescence emission intensity of K4Fe(CN)6-K3Fe(CN)6-luminol system,the prepared micropipe-chip was used to analyze the uric acid in serum under the selective conditions.Results:The enhancing chemiluminescence intensity was proportional to uric acid concentration over a range 2.0×10-5~1.0×10-2 g/L.The detection limit(3σ) was 4.6×10-7 g/L.The relative standard deviation(RSD) was 3.09% and the recovery test results were 94.0%,99.7%,and 107.8%.Conclusion:The manufacture technique of micropipr-chip is simple but the proposed determination method of uric acid in human serum is sensitive,fast and convenient.

Key concepts: Chemiluminescence, Uric acid, Detection limit, Chemistry, Chromatography, Luminol, Relative standard deviation, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Flow injection chemiluminescence determination of uric acid with micropipe-chip — Research Paper | ScholarLens