Storage at -80 degrees C decreases the concentration of HPLC-detected urinary albumin: possible mechanisms and implications.

Lajos Markó, J. Cseh, Tamás Kőszegi, Zoltán Szabó, G Molnár, Márton Mohás, Nóra Szigeti, István Wittmann

Open publisher page 5 citations

Abstract

BACKGROUND: Urinary albumin is now measured by high-performance liquid chromatography (HPLC) which also detects albumin missed by traditional immunochemical methods. A predictive effect of HPLC-detected albuminuria on mortality has just been reported in the AusDiab study, measuring albuminuria with HPLC after 7 years of -80 degrees C storage. However, there are already some data suggesting that HPLC-detected albuminuria is affected by -80 degrees C storage. We aimed to measure changes in HPLC-detected albuminuria after 2.5 years and find the factors which may be responsible for this alteration. METHODS: Urinary albumin was measured by the US Food and Drug Administration approved HPLC Accumin kit. Total free sulfhydryl groups (TFSG) of urine samples were measured by Ellman's reagent. RESULTS: We found a significant 24% average decrease in HPLC-detected albuminuria and a correlation between the magnitude of decrease and urinary pH. We found a correlation between changes of urinary albumin dimeric to monomeric ratio of stored urine and pH; however, only changes of monomeric form were found to be significant. A correlation was also found between the TFSG of fresh urine samples and pH. Less TFSG could be detected, and a correlation between TFSG and pH was absent in stored urine. CONCLUSIONS: We conclude that measurement of albuminuria by HPLC in long-term -80 degrees stored urine gives unreliable results. Decrease of HPLC-detected albuminuria is pH-dependent and may be due to the reducing capacity of urine. Prospective studies need to decide whether the predictive properties of HPLC-detected albuminuria decrease during longterm storage.

About this research paper

What this paper is about

BACKGROUND: Urinary albumin is now measured by high-performance liquid chromatography (HPLC) which also detects albumin missed by traditional immunochemical methods. A predictive effect of HPLC-detected albuminuria on mortality has just been reported in the AusDiab study, measuring albuminuria with HPLC after 7 years of -80 degrees C storage. However, there are already some data suggesting that HPLC-detected albuminuria is affected by -80 degrees C storage. We aimed to measure changes in HPLC-detected albuminuria after 2.5 years and find the factors which may be responsible for this alteration. METHODS: Urinary albumin was measured by the US Food and Drug Administration approved HPLC Accumin kit. Total free sulfhydryl groups (TFSG) of urine samples were measured by Ellman's reagent. RESULTS: We found a significant 24% average decrease in HPLC-detected albuminuria and a correlation between the magnitude of decrease and urinary pH. We found a correlation between changes of urinary albumin dimeric to monomeric ratio of stored urine and pH; however, only changes of monomeric form were found to be significant. A correlation was also found between the TFSG of fresh urine samples and pH. Less TFSG could be detected, and a correlation between TFSG and pH was absent in stored urine. CONCLUSIONS: We conclude that measurement of albuminuria by HPLC in long-term -80 degrees stored urine gives unreliable results. Decrease of HPLC-detected albuminuria is pH-dependent and may be due to the reducing capacity of urine. Prospective studies need to decide whether the predictive properties of HPLC-detected albuminuria decrease during longterm storage.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Urinary albumin is now measured by high-performance liquid chromatography (HPLC) which also detects albumin missed by traditional immunochemical methods. A predictive effect of HPLC-detected albuminuria on mortality has just been reported in the AusDiab study, measuring albuminuria with HPLC after 7 years of -80 degrees C storage. However, there are already some data suggesting that HPLC-detected albuminuria is affected by -80 degrees C storage. We aimed to measure changes in HPLC-detected albuminuria after 2.5 years and find the factors which may be responsible for this alteration. METHODS: Urinary albumin was measured by the US Food and Drug Administration approved HPLC Accumin kit. Total free sulfhydryl groups (TFSG) of urine samples were measured by Ellman's reagent. RESULTS: We found a significant 24% average decrease in HPLC-detected albuminuria and a correlation between the magnitude of decrease and urinary pH. We found a correlation between changes of urinary albumin dimeric to monomeric ratio of stored urine and pH; however, only changes of monomeric form were found to be significant. A correlation was also found between the TFSG of fresh urine samples and pH. Less TFSG could be detected, and a correlation between TFSG and pH was absent in stored urine. CONCLUSIONS: We conclude that measurement of albuminuria by HPLC in long-term -80 degrees stored urine gives unreliable results. Decrease of HPLC-detected albuminuria is pH-dependent and may be due to the reducing capacity of urine. Prospective studies need to decide whether the predictive properties of HPLC-detected albuminuria decrease during longterm storage.

Key concepts: Albuminuria, High-performance liquid chromatography, Urine, Chromatography, Albumin, Medicine, Urinary system, Microalbuminuria