2007Zhonghua jianyan yixue zazhiRequires access

Quantitation of albumin in urine by HPLC and initial clinical application

Wang Yu-mi

Open publisher page 0 citations

Abstract

Objective To measure albumin in urine by HPLC and conduct primary clinical application Methods Solvent gradient and appropriate wave length was optimized and performance of the HPLC method was evaluated.Urine albumin of 46 patients with diabetes was measured.Results In standard and urine,retention time of Alb was 13.1 min.The linear measuring range extends to 1 820 mg/L.The lower limit of measurment for Alb was 4.2 mg/L.The intra-assay CV and the inter-assay CV were 3.36%,4.12% and 1.93%,1.97% at 24.5 mg/L and 546.9 mg/L of Alb respectively.Analytical recovery rate were 96.3%,98.2% and 97.5%.Microalbuminuria rate was 54.3% by HPLC,26.1% by immunoassay in 46 patients with diabetes.Conclusions Measurement of Alb in urine by HPLC is feasible as routine method until quantifying urinary total Alb conveniently.HPLC is the same to suit research for diabetic nephropathy and so on.

About this research paper

What this paper is about

Objective To measure albumin in urine by HPLC and conduct primary clinical application Methods Solvent gradient and appropriate wave length was optimized and performance of the HPLC method was evaluated.Urine albumin of 46 patients with diabetes was measured.Results In standard and urine,retention time of Alb was 13.1 min.The linear measuring range extends to 1 820 mg/L.The lower limit of measurment for Alb was 4.2 mg/L.The intra-assay CV and the inter-assay CV were 3.36%,4.12% and 1.93%,1.97% at 24.5 mg/L and 546.9 mg/L of Alb respectively.Analytical recovery rate were 96.3%,98.2% and 97.5%.Microalbuminuria rate was 54.3% by HPLC,26.1% by immunoassay in 46 patients with diabetes.Conclusions Measurement of Alb in urine by HPLC is feasible as routine method until quantifying urinary total Alb conveniently.HPLC is the same to suit research for diabetic nephropathy and so on.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To measure albumin in urine by HPLC and conduct primary clinical application Methods Solvent gradient and appropriate wave length was optimized and performance of the HPLC method was evaluated.Urine albumin of 46 patients with diabetes was measured.Results In standard and urine,retention time of Alb was 13.1 min.The linear measuring range extends to 1 820 mg/L.The lower limit of measurment for Alb was 4.2 mg/L.The intra-assay CV and the inter-assay CV were 3.36%,4.12% and 1.93%,1.97% at 24.5 mg/L and 546.9 mg/L of Alb respectively.Analytical recovery rate were 96.3%,98.2% and 97.5%.Microalbuminuria rate was 54.3% by HPLC,26.1% by immunoassay in 46 patients with diabetes.Conclusions Measurement of Alb in urine by HPLC is feasible as routine method until quantifying urinary total Alb conveniently.HPLC is the same to suit research for diabetic nephropathy and so on.

Key concepts: Microalbuminuria, High-performance liquid chromatography, Urine, Chromatography, Albumin, Chemistry, Detection limit, Diabetic nephropathy

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitation of albumin in urine by HPLC and initial clinical application — Research Paper | ScholarLens