2007Clinical ChemistryRequires access

Apparent Loss of Urinary Albumin during Long-term Frozen Storage: HPLC vs Immunonephelometry

Jacoline Brinkman, Dick de Zeeuw, Hiddo J.L. Heerspink, Ronald T. Gansevoort, Ido P. Kema, Paul E. de Jong, Stephan J. L. Bakker

Open publisher page 47 citations

Abstract

BACKGROUND: Urinary albumin detection by immunonephelometry is decreased by approximately 30% in samples that have been frozen at -20 degrees C. An HPLC method for assessment of urinary albumin that detects immunoreactive and immunochemically nonreactive albumin has been introduced as an alternative to immunonephelometry. We investigated whether this technique is affected by sample temperature, particularly freezing. METHODS: Urine samples (n = 295) were collected from the general population (Prevention of Renal and Vascular End-Stage Disease Study). Samples were assessed by both immunonephelometry and HPLC when fresh and after storage at -20 degrees C for 4, 8, and 12 months and at -80 degrees C for 12 months. RESULTS: With immunonephelometry, storage for 4, 8, and 12 months at -20 degrees C resulted in mean (SD) urine albumin changes of -21% (29%), -28% (29%), and -34% (31) (P <0.001 for trend). Storage at -80 degrees C resulted in a 5% (19%) change after 12 months of storage (not significant). With HPLC, storage for 4, 8, and 12 months at -20 degrees C resulted in urine albumin changes of -33% (28%), -43% (24%), and -55% (21%; P <0.001 vs immunonephelometry). Storage at -80 degrees C resulted in a -29% (29%) change (P <0.001 vs immunonephelometry). CONCLUSION: Loss of albumin after freezing urine depends not only on freezing temperature but also on detection method. Detection of albumin by immunonephelometry appears to be significantly less influenced by freezing than detection by HPLC. Storage at -80 degrees C appears to prevent loss when using immunonephelometry, whereas HPLC still shows considerable loss even when urine is frozen at -80 degrees C. We propose that for reliable measurement of urine albumin, fresh samples should be used.

About this research paper

What this paper is about

BACKGROUND: Urinary albumin detection by immunonephelometry is decreased by approximately 30% in samples that have been frozen at -20 degrees C. An HPLC method for assessment of urinary albumin that detects immunoreactive and immunochemically nonreactive albumin has been introduced as an alternative to immunonephelometry. We investigated whether this technique is affected by sample temperature, particularly freezing. METHODS: Urine samples (n = 295) were collected from the general population (Prevention of Renal and Vascular End-Stage Disease Study). Samples were assessed by both immunonephelometry and HPLC when fresh and after storage at -20 degrees C for 4, 8, and 12 months and at -80 degrees C for 12 months. RESULTS: With immunonephelometry, storage for 4, 8, and 12 months at -20 degrees C resulted in mean (SD) urine albumin changes of -21% (29%), -28% (29%), and -34% (31) (P <0.001 for trend). Storage at -80 degrees C resulted in a 5% (19%) change after 12 months of storage (not significant). With HPLC, storage for 4, 8, and 12 months at -20 degrees C resulted in urine albumin changes of -33% (28%), -43% (24%), and -55% (21%; P <0.001 vs immunonephelometry). Storage at -80 degrees C resulted in a -29% (29%) change (P <0.001 vs immunonephelometry). CONCLUSION: Loss of albumin after freezing urine depends not only on freezing temperature but also on detection method. Detection of albumin by immunonephelometry appears to be significantly less influenced by freezing than detection by HPLC. Storage at -80 degrees C appears to prevent loss when using immunonephelometry, whereas HPLC still shows considerable loss even when urine is frozen at -80 degrees C. We propose that for reliable measurement of urine albumin, fresh samples should be used.

Why it matters

OpenAlex reports 47 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Urinary albumin detection by immunonephelometry is decreased by approximately 30% in samples that have been frozen at -20 degrees C. An HPLC method for assessment of urinary albumin that detects immunoreactive and immunochemically nonreactive albumin has been introduced as an alternative to immunonephelometry. We investigated whether this technique is affected by sample temperature, particularly freezing. METHODS: Urine samples (n = 295) were collected from the general population (Prevention of Renal and Vascular End-Stage Disease Study). Samples were assessed by both immunonephelometry and HPLC when fresh and after storage at -20 degrees C for 4, 8, and 12 months and at -80 degrees C for 12 months. RESULTS: With immunonephelometry, storage for 4, 8, and 12 months at -20 degrees C resulted in mean (SD) urine albumin changes of -21% (29%), -28% (29%), and -34% (31) (P <0.001 for trend). Storage at -80 degrees C resulted in a 5% (19%) change after 12 months of storage (not significant). With HPLC, storage for 4, 8, and 12 months at -20 degrees C resulted in urine albumin changes of -33% (28%), -43% (24%), and -55% (21%; P <0.001 vs immunonephelometry). Storage at -80 degrees C resulted in a -29% (29%) change (P <0.001 vs immunonephelometry). CONCLUSION: Loss of albumin after freezing urine depends not only on freezing temperature but also on detection method. Detection of albumin by immunonephelometry appears to be significantly less influenced by freezing than detection by HPLC. Storage at -80 degrees C appears to prevent loss when using immunonephelometry, whereas HPLC still shows considerable loss even when urine is frozen at -80 degrees C. We propose that for reliable measurement of urine albumin, fresh samples should be used.

Key concepts: Albumin, Urine, Chromatography, High-performance liquid chromatography, Urinary system, Population, Medicine, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Apparent Loss of Urinary Albumin during Long-term Frozen Storage: HPLC vs Immunonephelometry — Research Paper | ScholarLens