[Association between plasma adiponectin level and in-stent restenosis after coronary stenting].
Qin Qin, Yaru Lu, Yang Li, Lu Kou, Jinping Feng, Gang Chen, Chunjie Li, Zhao Bing-rang
Abstract
Qin Qin, Yaru Lu, Yang Li, Lu Kou, Jinping Feng, Gang Chen, Chunjie Li, Zhao Bing-rang
Abstract
OBJECTIVE: The purpose of the present study was to identify the relationship between the plasma level of adiponectin and in-stent restenosis of patients with coronary heart disease after coronary stenting. METHOD: The study population comprised 119 individuals (92 men) who underwent stent implantation, including 65 subjects without in-stent restenosis (group A) and 54 patients with in-stent restenosis (group B). The level of plasma adiponectin was measured using ELISA. Coronary angiography was performed immediately before and after implanting stent and 9 - 12 months later. RESULTS: Baseline characteristics including drug use after PCI were similar between the groups. The rate of implanting bare metal stent is 8 (12.31%) and 6 (11.11%), TAXUS drug-eluting stent is 11 (16.92%) and 10 (18.52%) and CYPHER drug-eluting stent is 46 (70.77%) and 38 (70.37%) respectively (all P > 0.05). Plasma level of adiponectin in patient of group A was significantly higher than that in group B [(15.16 +/- 5.02) mg/L vs. (10.01 +/- 4.93) mg/L, P < 0.05]. The quantitative coronary angiography (QCA) showed that lesion length was similar between groups [(15.82 +/- 6.67) mm vs. (13.40 +/- 4.20) mm, P > 0.05], minimum lumen diameter (MLD) and stenosis rate were also similar before and after implanting stent (P > 0.05) and acute gain was (1.48 +/- 0.65) mm vs. (1.19 +/- 0.37) mm (P > 0.05). MLD was higher in group A than that in group B [(2.55 +/- 0.53) mm vs. (0.57 +/- 0.60) mm, P < 0.01] at 9 - 12 months follow up. Restenosis rate [(24.2 +/- 11.2)% vs.(81.0 +/- 19.1)%, P < 0.01] and late lumen loss [(0.50 +/- 0.34) mm vs. (1.60 +/- 0.54) mm, P < 0.01] were lower in group A than in group B. CONCLUSIONS: The lower plasma adiponectin level might be associated with in-stent restenosis after coronary stenting.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: The purpose of the present study was to identify the relationship between the plasma level of adiponectin and in-stent restenosis of patients with coronary heart disease after coronary stenting. METHOD: The study population comprised 119 individuals (92 men) who underwent stent implantation, including 65 subjects without in-stent restenosis (group A) and 54 patients with in-stent restenosis (group B). The level of plasma adiponectin was measured using ELISA. Coronary angiography was performed immediately before and after implanting stent and 9 - 12 months later. RESULTS: Baseline characteristics including drug use after PCI were similar between the groups. The rate of implanting bare metal stent is 8 (12.31%) and 6 (11.11%), TAXUS drug-eluting stent is 11 (16.92%) and 10 (18.52%) and CYPHER drug-eluting stent is 46 (70.77%) and 38 (70.37%) respectively (all P > 0.05). Plasma level of adiponectin in patient of group A was significantly higher than that in group B [(15.16 +/- 5.02) mg/L vs. (10.01 +/- 4.93) mg/L, P < 0.05]. The quantitative coronary angiography (QCA) showed that lesion length was similar between groups [(15.82 +/- 6.67) mm vs. (13.40 +/- 4.20) mm, P > 0.05], minimum lumen diameter (MLD) and stenosis rate were also similar before and after implanting stent (P > 0.05) and acute gain was (1.48 +/- 0.65) mm vs. (1.19 +/- 0.37) mm (P > 0.05). MLD was higher in group A than that in group B [(2.55 +/- 0.53) mm vs. (0.57 +/- 0.60) mm, P < 0.01] at 9 - 12 months follow up. Restenosis rate [(24.2 +/- 11.2)% vs.(81.0 +/- 19.1)%, P < 0.01] and late lumen loss [(0.50 +/- 0.34) mm vs. (1.60 +/- 0.54) mm, P < 0.01] were lower in group A than in group B. CONCLUSIONS: The lower plasma adiponectin level might be associated with in-stent restenosis after coronary stenting.
Key concepts: Medicine, Restenosis, Adiponectin, Stent, Internal medicine, Cardiology, Bare-metal stent, Drug-eluting stent