OBJECTIVES: To compare the volume of in-stent neointimal proliferation, assessed by intravascular ultrasound (IVUS), at 6-month follow-up after implantation of a coronary Carbofilm-coated stent (Tecnic Carbostent, Sorin Biomedica Cardio, Saluggia, Italy) versus a conventional 316 L stent (Rx Multi-Link Penta, Abbott Laboratories, Abbott Park, IL). BACKGROUND: Many trials suggest that stent characteristics and coating could be important determinants of restenosis. METHODS: From October 2004 to May 2005, 63 patients were randomized to Tecnic (T, n = 30) or Penta (P, n = 33). The primary end-point was in-stent volume of neointimal hyperplasia (NIH) measured by IVUS at 6 months. The secondary end-points included binary restenosis, minimal luminal diameter (MLD), target lesion revascularization, and major adverse cardiac events. RESULTS: There were no significant differences between T and P as to mean age, male gender, clinical status, complexity of the lesion, lesion length, reference vessel diameter before percutaneous coronary intervention (PCI), MLD pre-PCI, and stent-to-artery ratio. However, MLD poststenting was greater in P group than T group (2.81 +/- 0.45 mm vs. 2.49 +/- 0.33 mm, P < 0.002). At 6 months, angiographic late lumen loss (0.61 +/- 0.51 mm vs. 0.92 +/- 0.61 mm, P < 0.043), in-stent obstruction (25.86 +/- 16.48% vs. 38.33 +/- 19.56%, P = 0.021), and in-stent late loss volume (31.62 +/- 29.75 mm(3) vs. 57.28 +/- 37.16 mm(3), P = 0.016) were significantly lower in T group than in P group. CONCLUSION: Penta stent appears to offer a better deployment and a larger MLD post-PCI than Carbofilm-coated stent. However, a thicker NIH was observed on Penta stent at 6-month follow-up, when compared to Tecnic.

About this research paper

What this paper is about

OBJECTIVES: To compare the volume of in-stent neointimal proliferation, assessed by intravascular ultrasound (IVUS), at 6-month follow-up after implantation of a coronary Carbofilm-coated stent (Tecnic Carbostent, Sorin Biomedica Cardio, Saluggia, Italy) versus a conventional 316 L stent (Rx Multi-Link Penta, Abbott Laboratories, Abbott Park, IL). BACKGROUND: Many trials suggest that stent characteristics and coating could be important determinants of restenosis. METHODS: From October 2004 to May 2005, 63 patients were randomized to Tecnic (T, n = 30) or Penta (P, n = 33). The primary end-point was in-stent volume of neointimal hyperplasia (NIH) measured by IVUS at 6 months. The secondary end-points included binary restenosis, minimal luminal diameter (MLD), target lesion revascularization, and major adverse cardiac events. RESULTS: There were no significant differences between T and P as to mean age, male gender, clinical status, complexity of the lesion, lesion length, reference vessel diameter before percutaneous coronary intervention (PCI), MLD pre-PCI, and stent-to-artery ratio. However, MLD poststenting was greater in P group than T group (2.81 +/- 0.45 mm vs. 2.49 +/- 0.33 mm, P < 0.002). At 6 months, angiographic late lumen loss (0.61 +/- 0.51 mm vs. 0.92 +/- 0.61 mm, P < 0.043), in-stent obstruction (25.86 +/- 16.48% vs. 38.33 +/- 19.56%, P = 0.021), and in-stent late loss volume (31.62 +/- 29.75 mm(3) vs. 57.28 +/- 37.16 mm(3), P = 0.016) were significantly lower in T group than in P group. CONCLUSION: Penta stent appears to offer a better deployment and a larger MLD post-PCI than Carbofilm-coated stent. However, a thicker NIH was observed on Penta stent at 6-month follow-up, when compared to Tecnic.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: To compare the volume of in-stent neointimal proliferation, assessed by intravascular ultrasound (IVUS), at 6-month follow-up after implantation of a coronary Carbofilm-coated stent (Tecnic Carbostent, Sorin Biomedica Cardio, Saluggia, Italy) versus a conventional 316 L stent (Rx Multi-Link Penta, Abbott Laboratories, Abbott Park, IL). BACKGROUND: Many trials suggest that stent characteristics and coating could be important determinants of restenosis. METHODS: From October 2004 to May 2005, 63 patients were randomized to Tecnic (T, n = 30) or Penta (P, n = 33). The primary end-point was in-stent volume of neointimal hyperplasia (NIH) measured by IVUS at 6 months. The secondary end-points included binary restenosis, minimal luminal diameter (MLD), target lesion revascularization, and major adverse cardiac events. RESULTS: There were no significant differences between T and P as to mean age, male gender, clinical status, complexity of the lesion, lesion length, reference vessel diameter before percutaneous coronary intervention (PCI), MLD pre-PCI, and stent-to-artery ratio. However, MLD poststenting was greater in P group than T group (2.81 +/- 0.45 mm vs. 2.49 +/- 0.33 mm, P < 0.002). At 6 months, angiographic late lumen loss (0.61 +/- 0.51 mm vs. 0.92 +/- 0.61 mm, P < 0.043), in-stent obstruction (25.86 +/- 16.48% vs. 38.33 +/- 19.56%, P = 0.021), and in-stent late loss volume (31.62 +/- 29.75 mm(3) vs. 57.28 +/- 37.16 mm(3), P = 0.016) were significantly lower in T group than in P group. CONCLUSION: Penta stent appears to offer a better deployment and a larger MLD post-PCI than Carbofilm-coated stent. However, a thicker NIH was observed on Penta stent at 6-month follow-up, when compared to Tecnic.

Key concepts: Medicine, Restenosis, Stent, Intravascular ultrasound, Conventional PCI, Percutaneous coronary intervention, Neointimal hyperplasia, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Does Carbofilm Coating Affect In‐Stent Intimal Proliferation? A Randomized Trial Comparing Rx Multi‐Link Penta and Tecnic Carbostent™ Stents: SIROCCO Trial — Research Paper | ScholarLens