1999Journal of the American Veterinary Medical AssociationOpen access

Tracheal rupture in cats: 16 cases (1983–1998)

Elizabeth M. Hardie, Gary J. Spodnick, Stephen D. Gilson, John Benson, Eleanor C. Hawkins

Open full text 93 citations

Abstract

OBJECTIVE: To determine causes of tracheal rupture in cats and the mechanism of injury. DESIGN: A retrospective study was conducted to identify cats with tracheal rupture. A second study was conducted to establish mechanism of injury, and a third study was conducted to determine volume of air needed to obtain an airtight seal when inflating the cuff of an endotracheal tube in a cat. ANIMALS: 16 cats with clinical signs of tracheal rupture, 10 cat cadavers, and 20 clinically normal cats that were undergoing anesthesia. PROCEDURES: Details were extracted from medical records of 16 cats with tracheal rupture (9 treated surgically and 7 treated conservatively). For the cadaver study, the trachea of each cat cadaver was intubated and observed during overinflation of the endotracheal tube cuff. For clinically normal cats, volume of air needed to obtain an airtight seal for the endotracheal tube was recorded. RESULTS: Most ruptures were associated with cats anesthetized for dental procedures. Clinical signs associated with tracheal rupture included subcutaneous emphysema, coughing, gagging, dyspnea, anorexia, and fever. Tracheoscopy was the method of choice for documenting tracheal rupture. Surgical and conservative management were successfully used, unless the injury extended to the carina. In the cadaver study, overinflation of the endotracheal tube cuff with > 6 ml of air resulted in tracheal rupture in 7 of 10 cadavers. For clinically normal cats, the volume of air (mean +/- SD) needed to obtain an airtight seal was 1.6 +/- 0.7 ml. CLINICAL IMPLICATIONS: Overinflation of an endotracheal tube cuff may result in tracheal rupture in cats.

Open-access reader

About this research paper

What this paper is about

OBJECTIVE: To determine causes of tracheal rupture in cats and the mechanism of injury. DESIGN: A retrospective study was conducted to identify cats with tracheal rupture. A second study was conducted to establish mechanism of injury, and a third study was conducted to determine volume of air needed to obtain an airtight seal when inflating the cuff of an endotracheal tube in a cat. ANIMALS: 16 cats with clinical signs of tracheal rupture, 10 cat cadavers, and 20 clinically normal cats that were undergoing anesthesia. PROCEDURES: Details were extracted from medical records of 16 cats with tracheal rupture (9 treated surgically and 7 treated conservatively). For the cadaver study, the trachea of each cat cadaver was intubated and observed during overinflation of the endotracheal tube cuff. For clinically normal cats, volume of air needed to obtain an airtight seal for the endotracheal tube was recorded. RESULTS: Most ruptures were associated with cats anesthetized for dental procedures. Clinical signs associated with tracheal rupture included subcutaneous emphysema, coughing, gagging, dyspnea, anorexia, and fever. Tracheoscopy was the method of choice for documenting tracheal rupture. Surgical and conservative management were successfully used, unless the injury extended to the carina. In the cadaver study, overinflation of the endotracheal tube cuff with > 6 ml of air resulted in tracheal rupture in 7 of 10 cadavers. For clinically normal cats, the volume of air (mean +/- SD) needed to obtain an airtight seal was 1.6 +/- 0.7 ml. CLINICAL IMPLICATIONS: Overinflation of an endotracheal tube cuff may result in tracheal rupture in cats.

Why it matters

OpenAlex reports 93 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To determine causes of tracheal rupture in cats and the mechanism of injury. DESIGN: A retrospective study was conducted to identify cats with tracheal rupture. A second study was conducted to establish mechanism of injury, and a third study was conducted to determine volume of air needed to obtain an airtight seal when inflating the cuff of an endotracheal tube in a cat. ANIMALS: 16 cats with clinical signs of tracheal rupture, 10 cat cadavers, and 20 clinically normal cats that were undergoing anesthesia. PROCEDURES: Details were extracted from medical records of 16 cats with tracheal rupture (9 treated surgically and 7 treated conservatively). For the cadaver study, the trachea of each cat cadaver was intubated and observed during overinflation of the endotracheal tube cuff. For clinically normal cats, volume of air needed to obtain an airtight seal for the endotracheal tube was recorded. RESULTS: Most ruptures were associated with cats anesthetized for dental procedures. Clinical signs associated with tracheal rupture included subcutaneous emphysema, coughing, gagging, dyspnea, anorexia, and fever. Tracheoscopy was the method of choice for documenting tracheal rupture. Surgical and conservative management were successfully used, unless the injury extended to the carina. In the cadaver study, overinflation of the endotracheal tube cuff with > 6 ml of air resulted in tracheal rupture in 7 of 10 cadavers. For clinically normal cats, the volume of air (mean +/- SD) needed to obtain an airtight seal was 1.6 +/- 0.7 ml. CLINICAL IMPLICATIONS: Overinflation of an endotracheal tube cuff may result in tracheal rupture in cats.

Key concepts: Medicine, Cuff, CATS, Cadaver, Surgery, Tracheal tube, Anesthesia, Endotracheal tube

Related papers

Back to paper searchBrowse research topicsOriginal source
Tracheal rupture in cats: 16 cases (1983–1998) — Research Paper | ScholarLens