2006AnaesthesiaOpen access

An in vitro study of the compliance of paediatric tracheal tube cuffs and tracheal wall pressure

Vera Bernet, Alexander Dullenkopf, Vincenzo Cannizzaro, K. Stutz, M. Weiss

Open full text 22 citations

Abstract

Cuff volume-pressure curves and cuff pressure-tracheal wall pressure relationships were investigated in eight brands of currently available cuffed, paediatric tracheal tubes with internal diameters of 5.0 mm. Cuff volume-pressure curves were measured with the cuff unrestricted and with the cuff placed within a tracheal model with wall pressure measurements. With the tracheal tube cuffs, unrestricted cuff compliance at 20 cmH(2)O cuff pressure varied between 0.06 and 0.3 ml x cmH(2)O(-1). With the cuff restricted within the model trachea, all tracheal tube cuffs became considerably less compliant (0.01-0.09 ml x cmH(2)O(-1)). We found tracheal wall pressure was similar to the cuff pressure as long as the resulting cuff diameter was sufficiently large freely to drape the inner tracheal wall. We found that, regardless of whether a higher or lower compliant tube cuff was used, cuff hyperinflation uniformly resulted in potentially compromised tracheal mucosal blood flow; cuff pressure monitoring using cuff pressure limitation is therefore strongly recommended.

Open-access reader

About this research paper

What this paper is about

Cuff volume-pressure curves and cuff pressure-tracheal wall pressure relationships were investigated in eight brands of currently available cuffed, paediatric tracheal tubes with internal diameters of 5.0 mm. Cuff volume-pressure curves were measured with the cuff unrestricted and with the cuff placed within a tracheal model with wall pressure measurements. With the tracheal tube cuffs, unrestricted cuff compliance at 20 cmH(2)O cuff pressure varied between 0.06 and 0.3 ml x cmH(2)O(-1). With the cuff restricted within the model trachea, all tracheal tube cuffs became considerably less compliant (0.01-0.09 ml x cmH(2)O(-1)). We found tracheal wall pressure was similar to the cuff pressure as long as the resulting cuff diameter was sufficiently large freely to drape the inner tracheal wall. We found that, regardless of whether a higher or lower compliant tube cuff was used, cuff hyperinflation uniformly resulted in potentially compromised tracheal mucosal blood flow; cuff pressure monitoring using cuff pressure limitation is therefore strongly recommended.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Cuff volume-pressure curves and cuff pressure-tracheal wall pressure relationships were investigated in eight brands of currently available cuffed, paediatric tracheal tubes with internal diameters of 5.0 mm. Cuff volume-pressure curves were measured with the cuff unrestricted and with the cuff placed within a tracheal model with wall pressure measurements. With the tracheal tube cuffs, unrestricted cuff compliance at 20 cmH(2)O cuff pressure varied between 0.06 and 0.3 ml x cmH(2)O(-1). With the cuff restricted within the model trachea, all tracheal tube cuffs became considerably less compliant (0.01-0.09 ml x cmH(2)O(-1)). We found tracheal wall pressure was similar to the cuff pressure as long as the resulting cuff diameter was sufficiently large freely to drape the inner tracheal wall. We found that, regardless of whether a higher or lower compliant tube cuff was used, cuff hyperinflation uniformly resulted in potentially compromised tracheal mucosal blood flow; cuff pressure monitoring using cuff pressure limitation is therefore strongly recommended.

Key concepts: Cuff, Medicine, Tracheal tube, Compliance (psychology), Tube (container), Anesthesia, Surgery, Intubation

Related papers

Back to paper searchBrowse research topicsOriginal source
An in vitro study of the compliance of paediatric tracheal tube cuffs and tracheal wall pressure — Research Paper | ScholarLens