Nitrous oxide diffusion into tracheal tube cuffs: comparison of five different tracheal tube cuffs
Alexander Dullenkopf, Andreas Gerber, M. Weiss
Abstract
Alexander Dullenkopf, Andreas Gerber, M. Weiss
Abstract
BACKGROUND: The aim of this study was to investigate cuff compliance and cuff pressure during nitrous oxide exposure in the recently introduced Microcuff tracheal tube with a polyurethane cuff (Microcuff GmbH, Weinheim, Germany), and to compare it to conventional tracheal tubes with PVC cuffs. METHODS: In an in vitro set up, five cuffed tracheal tubes (ID 7.0 mm) from different manufacturers (Microcuff HVLP, Portex Profile Soft Seal, Mallinckrodt HiLo, Rüsch Super Safety Clear and Sheridan CF) were studied. Pressure-volume curves were assessed and changes of cuff pressure during exposure to nitrous oxide (for 60 min; 66% N(2)O in oxygen) were recorded without and with restriction of the cuff in a trachea model. Each experiment was performed four times using two exemplars of each tube twice. Sixty-minute values of the Microcuff group were compared with the other groups using the Mann- Whitney test (P < 0.05). RESULTS: The Microcuff polyurethane cuff demonstrated an intermediate cuff compliance but the highest cuff pressure increase during nitrous oxide exposure under unrestricted conditions. When inflated within the artificial trachea its cuff compliance became the highest of all tested tracheal tubes. However, exposure to N(2)O, again led to a rapid increase in cuff pressure. CONCLUSION: The ultra-thin polyurethane tube cuff demonstrated higher permeability for nitrous oxide than conventional PVC cuffs and led to a rapid cuff pressure increase when exposed to N(2)O. Routinely checking of cuff-pressure or filling the cuff with nitrous oxide are more important than the brand of tube used.
OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: The aim of this study was to investigate cuff compliance and cuff pressure during nitrous oxide exposure in the recently introduced Microcuff tracheal tube with a polyurethane cuff (Microcuff GmbH, Weinheim, Germany), and to compare it to conventional tracheal tubes with PVC cuffs. METHODS: In an in vitro set up, five cuffed tracheal tubes (ID 7.0 mm) from different manufacturers (Microcuff HVLP, Portex Profile Soft Seal, Mallinckrodt HiLo, Rüsch Super Safety Clear and Sheridan CF) were studied. Pressure-volume curves were assessed and changes of cuff pressure during exposure to nitrous oxide (for 60 min; 66% N(2)O in oxygen) were recorded without and with restriction of the cuff in a trachea model. Each experiment was performed four times using two exemplars of each tube twice. Sixty-minute values of the Microcuff group were compared with the other groups using the Mann- Whitney test (P < 0.05). RESULTS: The Microcuff polyurethane cuff demonstrated an intermediate cuff compliance but the highest cuff pressure increase during nitrous oxide exposure under unrestricted conditions. When inflated within the artificial trachea its cuff compliance became the highest of all tested tracheal tubes. However, exposure to N(2)O, again led to a rapid increase in cuff pressure. CONCLUSION: The ultra-thin polyurethane tube cuff demonstrated higher permeability for nitrous oxide than conventional PVC cuffs and led to a rapid cuff pressure increase when exposed to N(2)O. Routinely checking of cuff-pressure or filling the cuff with nitrous oxide are more important than the brand of tube used.
Key concepts: Cuff, Tracheal tube, Medicine, Nitrous oxide, Anesthesia, Tube (container), Mallinckrodt, Seal (emblem)