2007PubMedRequires access

[Determination of trace impurities in high purity titanium dioxide by high resolution inductively coupled plasma mass spectrometry].

Xiao‐Mei He, Xie Hua-lin, Nie Xi-du, Yougen Tang

Open publisher page 3 citations

Abstract

An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for the rapid simultaneous determination of twenty six elements (Be, Na, Mg, Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Mo, Cd, Sn, Sb, Ba, Ce, Nd, Sm, Pt, Pb and Bi) in high purity titanium dioxide was described. Samples were decomposed by (NH4)2SO4 and H2SO4. Most of the spectral interferences could be avoided by measuring in the high-resolution mode. The matrix effects due to the presence of excess sulfuric acid and Ti were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits are 0.004-0.63 microg x g(-1), the recovery ratio is 87.6%-106.4%, and the RSD is less than 3.5%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity titanium dioxide with satisfactory results.

About this research paper

What this paper is about

An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for the rapid simultaneous determination of twenty six elements (Be, Na, Mg, Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Mo, Cd, Sn, Sb, Ba, Ce, Nd, Sm, Pt, Pb and Bi) in high purity titanium dioxide was described. Samples were decomposed by (NH4)2SO4 and H2SO4. Most of the spectral interferences could be avoided by measuring in the high-resolution mode. The matrix effects due to the presence of excess sulfuric acid and Ti were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits are 0.004-0.63 microg x g(-1), the recovery ratio is 87.6%-106.4%, and the RSD is less than 3.5%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity titanium dioxide with satisfactory results.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for the rapid simultaneous determination of twenty six elements (Be, Na, Mg, Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Mo, Cd, Sn, Sb, Ba, Ce, Nd, Sm, Pt, Pb and Bi) in high purity titanium dioxide was described. Samples were decomposed by (NH4)2SO4 and H2SO4. Most of the spectral interferences could be avoided by measuring in the high-resolution mode. The matrix effects due to the presence of excess sulfuric acid and Ti were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits are 0.004-0.63 microg x g(-1), the recovery ratio is 87.6%-106.4%, and the RSD is less than 3.5%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity titanium dioxide with satisfactory results.

Key concepts: Impurity, Inductively coupled plasma mass spectrometry, Analytical Chemistry (journal), Inductively coupled plasma, Chemistry, Mass spectrometry, Titanium dioxide, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of trace impurities in high purity titanium dioxide by high resolution inductively coupled plasma mass spectrometry]. — Research Paper | ScholarLens