2013PubMedRequires access

[Determination of impurity elements in the positive electrode material LiMn2O4 by inductively coupled plasma mass spectrometry].

Zhu Qian-hua

Open publisher page 0 citations

Abstract

Samples of LiMn2O4 were digested by microwave digestion, and impurity elements amounts of Na, Mg, Al, K, Ca, Ti, Cr, Fe, Cu, Zn, As, Ag, Cd and Pb in sample solutions were determined by inductively coupled plasma mass spectrometry (ICP-MS). Sample preparation was achieved by digestion with HNO3 + HCl in a closed-vessel microwave system. The effects of mass spectrum interference were studied. Sc, Rh and Tl as internal standard elements were used to compensate matrix effect and signal drift. Under the optimal conditions, the detection limits of the 14 elements are in the range of 0.007-0.209 microg x L(-1). The recovery was 92.66%-108.34% by adding standard recovery experiment, and the relative standard deviation (RSD) was less than 4.80% for all the elements. This method was simple, sensitive and precise, which could satisfy the sample examination request and provide scientific rationale for determining impurity elements of LiMn2O4.

About this research paper

What this paper is about

Samples of LiMn2O4 were digested by microwave digestion, and impurity elements amounts of Na, Mg, Al, K, Ca, Ti, Cr, Fe, Cu, Zn, As, Ag, Cd and Pb in sample solutions were determined by inductively coupled plasma mass spectrometry (ICP-MS). Sample preparation was achieved by digestion with HNO3 + HCl in a closed-vessel microwave system. The effects of mass spectrum interference were studied. Sc, Rh and Tl as internal standard elements were used to compensate matrix effect and signal drift. Under the optimal conditions, the detection limits of the 14 elements are in the range of 0.007-0.209 microg x L(-1). The recovery was 92.66%-108.34% by adding standard recovery experiment, and the relative standard deviation (RSD) was less than 4.80% for all the elements. This method was simple, sensitive and precise, which could satisfy the sample examination request and provide scientific rationale for determining impurity elements of LiMn2O4.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Samples of LiMn2O4 were digested by microwave digestion, and impurity elements amounts of Na, Mg, Al, K, Ca, Ti, Cr, Fe, Cu, Zn, As, Ag, Cd and Pb in sample solutions were determined by inductively coupled plasma mass spectrometry (ICP-MS). Sample preparation was achieved by digestion with HNO3 + HCl in a closed-vessel microwave system. The effects of mass spectrum interference were studied. Sc, Rh and Tl as internal standard elements were used to compensate matrix effect and signal drift. Under the optimal conditions, the detection limits of the 14 elements are in the range of 0.007-0.209 microg x L(-1). The recovery was 92.66%-108.34% by adding standard recovery experiment, and the relative standard deviation (RSD) was less than 4.80% for all the elements. This method was simple, sensitive and precise, which could satisfy the sample examination request and provide scientific rationale for determining impurity elements of LiMn2O4.

Key concepts: Inductively coupled plasma mass spectrometry, Analytical Chemistry (journal), Impurity, Microwave digestion, Chemistry, Mass spectrometry, Inductively coupled plasma, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of impurity elements in the positive electrode material LiMn2O4 by inductively coupled plasma mass spectrometry]. — Research Paper | ScholarLens