[Determination of impurity elements in the positive electrode material LiMn2O4 by inductively coupled plasma mass spectrometry].
Zhu Qian-hua
Abstract
Zhu Qian-hua
Abstract
Samples of LiMn2O4 were digested by microwave digestion, and impurity elements amounts of Na, Mg, Al, K, Ca, Ti, Cr, Fe, Cu, Zn, As, Ag, Cd and Pb in sample solutions were determined by inductively coupled plasma mass spectrometry (ICP-MS). Sample preparation was achieved by digestion with HNO3 + HCl in a closed-vessel microwave system. The effects of mass spectrum interference were studied. Sc, Rh and Tl as internal standard elements were used to compensate matrix effect and signal drift. Under the optimal conditions, the detection limits of the 14 elements are in the range of 0.007-0.209 microg x L(-1). The recovery was 92.66%-108.34% by adding standard recovery experiment, and the relative standard deviation (RSD) was less than 4.80% for all the elements. This method was simple, sensitive and precise, which could satisfy the sample examination request and provide scientific rationale for determining impurity elements of LiMn2O4.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Samples of LiMn2O4 were digested by microwave digestion, and impurity elements amounts of Na, Mg, Al, K, Ca, Ti, Cr, Fe, Cu, Zn, As, Ag, Cd and Pb in sample solutions were determined by inductively coupled plasma mass spectrometry (ICP-MS). Sample preparation was achieved by digestion with HNO3 + HCl in a closed-vessel microwave system. The effects of mass spectrum interference were studied. Sc, Rh and Tl as internal standard elements were used to compensate matrix effect and signal drift. Under the optimal conditions, the detection limits of the 14 elements are in the range of 0.007-0.209 microg x L(-1). The recovery was 92.66%-108.34% by adding standard recovery experiment, and the relative standard deviation (RSD) was less than 4.80% for all the elements. This method was simple, sensitive and precise, which could satisfy the sample examination request and provide scientific rationale for determining impurity elements of LiMn2O4.
Key concepts: Inductively coupled plasma mass spectrometry, Analytical Chemistry (journal), Impurity, Microwave digestion, Chemistry, Mass spectrometry, Inductively coupled plasma, Detection limit